![EBK ELECTRICAL WIRING RESIDENTIAL](https://www.bartleby.com/isbn_cover_images/9781337516549/9781337516549_largeCoverImage.jpg)
Concept explainers
The following problems pertain to luminaires in clothes closets.
- a. Does the Code permit bare incandescent lamps to be installed in porcelain key-less or porcelain pull-chain lampholders? ________________
- b. Does the Code permit bare fluorescent lamp luminaires to be installed? ________________
- c. Does the Code permit pendant lampholders to be installed? ________________
- d. What is the minimum clearance from the storage area to surface-mounted incandescent luminaires? ________________
- e. What is the minimum clearance from the storage area to surface-mounted fluorescent luminaires? ________________
- f. What is the minimum distance between recessed incandescent or recessed fluorescent luminaires and the storage area? ________________
- g. Define the “storage area.”
______________________________________
______________________________________
______________________________________
______________________________________
______________________________________
______________________________________
- h. If a clothes hanging rod is installed where there is access from both sides, such as might be found in a large walk-in clothes closet, define the storage area under that rod.
___________________________________
___________________________________
a.
![Check Mark](/static/check-mark.png)
Find whether the code permits to install bare incandescent lamps in porcelain keyless or porcelain pull-chain lamp holders.
Answer to Problem 14R
No, the code does not permit to install bare incandescent lamps in porcelain keyless or porcelain pull-chain lamp holders.
Explanation of Solution
Discussion:
The National Electrical Code committee develops NEC - the standard electrical code, and the main objective for the origin of the code is to protect and safeguard people and elements from the electrical hazards. The codes for defining clothes closet luminaires are explained in an article NEC 410.16.
According to an article NEC 410.16(B), the incandescent luminaires with fully open or partially enclosed lamps and the pendant luminaires or pendant lamp holders are not permitted to be installed in a closet.
Therefore, the bare incandescent lamp that is an uncovered lamp is not permitted to be installed in a closet.
Conclusion:
Thus, the code does not permit to install bare incandescent lamps in porcelain keyless or porcelain pull-chain lamp holders.
b.
![Check Mark](/static/check-mark.png)
Find whether the code permits to install bare fluorescent lamp luminaires in a closet.
Answer to Problem 14R
Yes, the code permits to install bare fluorescent lamp luminaires in a closet.
Explanation of Solution
Discussion:
According to an article NEC 410.16(A)(2), the recessed fluorescent luminaires or surface-mounted luminaires are permitted to be installed in a closet.
Therefore, the bare fluorescent lamp luminaires, which are uncovered lamps, are permitted to be installed in a closet.
Conclusion:
Thus, the code permits to install bare fluorescent lamp luminaires in a closet.
c.
![Check Mark](/static/check-mark.png)
Find whether the code permits to install pendant lamp holders in a closet.
Answer to Problem 14R
No, the code does not permit to install pendant lamp holders in a closet.
Explanation of Solution
Discussion:
According to an article NEC 410.16(B), the incandescent luminaires with fully open or partially enclosed lamps and the pendant luminaires or pendant lamp holders are not permitted to be installed in a closet.
Conclusion:
Thus, the code does not permit to install pendant lamp holders in a closet.
d.
![Check Mark](/static/check-mark.png)
Find the minimum clearance distance from the storage area to surface-mounted incandescent luminaires.
Answer to Problem 14R
The minimum clearance distance from the storage area to surface-mounted incandescent luminaires is
Explanation of Solution
Discussion:
According to an article NEC 410.16(C)(1), the minimum clearance distance between surface-mounted incandescent or LED luminaires with fully enclosed light source that is permitted to be installed on the wall either above the ceiling or the door and the nearest point of a closet space is
Conclusion:
Thus, minimum clearance distance from the storage area to surface-mounted incandescent luminaires is
e.
![Check Mark](/static/check-mark.png)
Find the minimum clearance distance from the storage area to surface-mounted fluorescent luminaires.
Answer to Problem 14R
The minimum clearance distance from the storage area to surface-mounted fluorescent luminaires is
Explanation of Solution
Discussion:
According to an article NEC 410.16(C)(2), the minimum clearance distance between surface-mounted fluorescent luminaires, which are permitted to be installed on the wall either above the ceiling or the door and the nearest point of a closet space, is
Conclusion:
Thus, minimum clearance distance from the storage area to surface-mounted fluorescent luminaires is
f.
![Check Mark](/static/check-mark.png)
Find the minimum clearance distance between the storage area and recessed incandescent luminaires or fluorescent luminaires.
Answer to Problem 14R
The minimum clearance distance between the storage area and recessed incandescent luminaires or fluorescent luminaires is
Explanation of Solution
Discussion:
According to an article NEC 410.16(C)(3), the minimum clearance distance between recessed incandescent luminaires or LED luminaires with fully enclosed light source that is permitted to be installed on the wall above the ceiling or the door and the nearest point of a closet space is
Conclusion:
Thus, minimum clearance distance between the storage area and recessed incandescent luminaires or fluorescent luminaires is
g.
![Check Mark](/static/check-mark.png)
Define the term “storage area”.
Explanation of Solution
Discussion:
According to an article NEC 410.2, the volume is bounded by the back and sides of the closet walls and the planes that extend from the closet floor in vertical to the height of
Conclusion:
Thus, the term “storage area” is defined.
h.
![Check Mark](/static/check-mark.png)
Find the storage area space under the clothes hanging rod.
Answer to Problem 14R
The storage area space under the clothes hanging rod is
Explanation of Solution
Discussion:
According to an article NEC 410.2, the closet can provide access to both sides of the hanging rod; the space can include the volume that is below the highest rod and extends
Conclusion:
Thus, storage area space under the clothes hanging rod is
Want to see more full solutions like this?
Chapter 8 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Additional Engineering Textbook Solutions
Vector Mechanics for Engineers: Statics and Dynamics
Starting Out with Programming Logic and Design (5th Edition) (What's New in Computer Science)
Elementary Surveying: An Introduction To Geomatics (15th Edition)
Fluid Mechanics: Fundamentals and Applications
SURVEY OF OPERATING SYSTEMS
Starting Out with C++ from Control Structures to Objects (9th Edition)
- Solve by Pen and Paper not using chatgpt or AIarrow_forwardYou just got a job at Shin-Etsu Chemical growing Si crystals with different dopants. Howmuch Ga needs to be added to 800 kg of Si melt to achieve a 5-10 Ω.cm (measured at midheight) Si CZ crystal with the following characteristics: height: 7 ft, width: 12 inchesdiameter. Assume, angular rotation 10 RPM, melt viscosity 0.1 poise, pull velocity 2mm/min.a. Generate a plot of the doping distribution throughout the length of the crystal (CGa vs. fs ).b. If a second crystal were to be pulled out of the melt without replenishment of silicon nordopant what would be the average resistivity of this crystal (or resistivity at mid height)arrow_forwardDO NOT USE AI OR CHAT GPT NEED HANDWRITTEN SOLUTIONarrow_forward
- 7. Complete the following problems for the circuit below. (a) When VDD = 120V, What is the voltage drop V1 across the 7Ω resistor? (b) If the voltage source VDD is set to obtain I1 = 2A, find the value of VDD. (c) If I1 = 100A, What is the value of I2arrow_forwarda) In terms of n and p, how many state variables and how many inputs can you see in the system below? dx1 =x12x2 + 9u1 dt dx2 =x1+x3+3u2 dt dx3 = 4x1 +5x2 - 12x3 dt b) Derive the state space representation for the above system c) Determine whether the system is stable or not.arrow_forwardCircuit Logic. Match each statement to the proper circuit. All circuits have been drawn with a light (L) to represent the load, whether it is a motor, bell, light, or any other load. In addition, each switch is illustrated as a pushbutton whether it is a maintained switch, momentary contact switch, pushbutton, switch-on target, or any other type of switch.arrow_forward
- a) In terms of n and p, how many state variables and how many inputs can you see in the system below? dx1 = 4x1 = x2 dt dx2 =-3x12x2 +U1 dt b) Derive the state space representation for the above system c) Determine whether the system is stable or not.arrow_forwardmatch each statement to the proper circuit. All circuits have been drawn with a light (L) to represent the load, whether it is a motor, bell, light or any other load. In addition, each switch is illustrated as a push button whether it is maintained switch, momentary contact switch, pushbutton, switch-on target, or any other type of switch.arrow_forwarda) In terms of n and p, how many state variables and how many inputs can you see in the system below? dx1 =-7x1 + x2 + 5u1 dt dx2 =-11x1+x3 + 2u1 dt dx3 = -8x16u1 dt b) Derive the state space representation for the above system c) Determine whether the system is stable or not.arrow_forward
- Question 2 (20 points) a) In terms of n and p, how many state variables and how many inputs can you see in the system below? dx1 dt =x1- 2x2 dx2 = 3x1 - 4x2 dt b) Derive the state space representation for the above system c) Determine whether the system is stable or not.arrow_forwardStuck on the question. Please do not use AI, it will get the answer wrong.arrow_forwardConsider a particle confined in an infinite potential well as shown below and its wave function Solve the following problems. is derived as √(x) = A sin (TA), and energy E= H U 0 U=0 a x πλη 2ma² €30 (iii) Calculate the value of A. [Hint: The probability of finding the particle in 0arrow_forwardarrow_back_iosSEE MORE QUESTIONSarrow_forward_ios
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337516549/9781337516549_smallCoverImage.jpg)