Electrical Wiring Residential
18th Edition
ISBN: 9781285170954
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 7, Problem 8R
To determine
Find the class type and the protection type of the fluorescent ballasts for all indoor applications.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.
Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…
Fill in the blank
The resistance of a wire is 126.48 ohms at 1000C and 100 ohms at 300C. The temperature coefficient of this wire at 00C is ____________ per C0.
6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steel
Chapter 7 Solutions
Electrical Wiring Residential
Ch. 7 - Is it permissible to install a recessed luminaire...Ch. 7 - If a recessed luminaire without an integral...Ch. 7 - Thermal insulation is not permitted to be...Ch. 7 - Recessed luminaires are available for installation...Ch. 7 - Unless specifically designed, all recessed...Ch. 7 - Plans require the installation of surface-mounted...Ch. 7 - A recessed luminaire bears no marking indicating...Ch. 7 - Prob. 8RCh. 7 - Additional backup protection for ballasts can be...Ch. 7 - Prob. 10R
Ch. 7 - The Code places a maximum open-circuit voltage on...Ch. 7 - The letter E in a circle on a ballast nameplate...Ch. 7 - A 120-volt lamp fluorescent ballast for two...Ch. 7 - Can an incandescent lamp dimmer be used to control...Ch. 7 - A good rule-of-thumb to estimate the expected life...Ch. 7 - A post light has a 120-volt, 60-watt lamp...Ch. 7 - Define the following terms. a. A tap conductor is...Ch. 7 - Circle the correct answer for the following...Ch. 7 - Circle the correct answer for the following...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Grounding Lighting Fixtures. There are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors? Be sure and cite the code in your answers.arrow_forwardFor the 25ft tap rule the __________ of the smaller conductors must be not less than one third of the rating of the upstream over current protective devicesarrow_forwardElectrical plants Define the terms "Main column ." " Line ." " Protection earth " and " Operating eartharrow_forward
- A cone meter rod 2 cm diameter is drawn until its resistance is 100 times the initialresistance. Its length afterward is _________.arrow_forwardVoltages above ____________AC and ___________DC are always dangerous. Extra precautions should be considered as voltage levels are increased.arrow_forwardA device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forward
- iF AN AMMETER WAS CONNECTED BETWEEN SWITCH1 AND POTENTIOMETER R1, HOW MUCH CURRENT WOULD IT INDICATE AT E(min) and E(max) IE(min)=__________________________mAdc IE(max)=__________________________mAdcarrow_forwardTo testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward
- 12. Which Insulators can be used for both horizontal and vertical positioning? A. SUSPENSION TYPE INSULATORS B. SHACKLE TYPE INSULATORS C. PIN TYPE INSULATORS D. POST TYPE INSULATORSarrow_forward14: In a natural circulation solar water heater, collector has a glass cover on the top and an ________________ material at the bottom. a. Insulating b. Sheets c. Steel d. Tubes 15: text ____________ wind mill consists of narrow rims and wire spokes. a. Single bladed b. Vertical Axis c. Double bladed d. Multibladedarrow_forward21/ Which Insulators can be used for both horizontal and vertical positioning? A. PIN TYPE INSULATORS B. SHACKLE TYPE INSULATORS C. SUSPENSION TYPE INSULATORS D. POST TYPE INSULATORSarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT