Define the following terms.
- a. A tap conductor is ________________
_______________________________
- b. A fixture whip is _________________
_______________________________
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
8.a. A _______ conductor does not carry current during normal operation.A. neutralB. groundingC. phaseD. grounded8.b. "The complete path of an electric current" describes an electric(al)A. fault.B. circuit.C. source.D. component.
6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steel
13. Which of the following is a method for identifying a grounding terminal for connecting an equipmentgrounding conductor to a device?A. The letters EGCB. A green octagonal nutC. A red pressure wire connectorD. A green screw with a hexagon head
Chapter 7 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 7 - Is it permissible to install a recessed luminaire...Ch. 7 - If a recessed luminaire without an integral...Ch. 7 - Thermal insulation is not permitted to be...Ch. 7 - Recessed luminaires are available for installation...Ch. 7 - Unless specifically designed, all recessed...Ch. 7 - Plans require the installation of surface-mounted...Ch. 7 - A recessed luminaire bears no marking indicating...Ch. 7 - Prob. 8RCh. 7 - Additional backup protection for ballasts can be...Ch. 7 - Prob. 10R
Ch. 7 - The Code places a maximum open-circuit voltage on...Ch. 7 - The letter E in a circle on a ballast nameplate...Ch. 7 - A 120-volt lamp fluorescent ballast for two...Ch. 7 - Can an incandescent lamp dimmer be used to control...Ch. 7 - A good rule-of-thumb to estimate the expected life...Ch. 7 - A post light has a 120-volt, 60-watt lamp...Ch. 7 - Define the following terms. a. A tap conductor is...Ch. 7 - Circle the correct answer for the following...Ch. 7 - Circle the correct answer for the following...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
For the “tank” circuit in Fig. 14.79, find the resonant frequency.
Figure 14.79
For Probs. 14.39, 14.71, and 1...
Fundamentals of Electric Circuits
Identify the type of input and output configuration for each diff-amp in Figure 18-35.
Electronics Fundamentals: Circuits, Devices & Applications
The voltage source of the circuit shown in Fig. P1.29 is given by s(t)=25cos(4104t45)(V). Obtain an expression ...
Fundamentals of Applied Electromagnetics (7th Edition)
Explain the main function of each of the following major components of a PLC: a. Processor module (CPU) b. I/O ...
Programmable Logic Controllers
Does the severity of an electric shock increase ordecrease with eh of the following changes? a. A decrease in t...
Electric Motors and Control Systems
What is the color code for a 365- five-band precision resistor with a tolerance of 5 percent?
ELECTRICITY FOR TRADES (LOOSELEAF)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 14: In a natural circulation solar water heater, collector has a glass cover on the top and an ________________ material at the bottom. a. Insulating b. Sheets c. Steel d. Tubes 15: text ____________ wind mill consists of narrow rims and wire spokes. a. Single bladed b. Vertical Axis c. Double bladed d. Multibladedarrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forwardTraining is required for: Qualified electricians only. Only those workers who work on or near exposed energized parts. Both those workers who work on or near exposed energized parts and those who do not. None of the above. a. b. C. d. Workers who are designated as "unqualified:" Do not need any training. Must become "qualified" within one year. a. b. Must not operate electrically powered equipment. Must be trained in safety-related work practices. C. d. Workers who are designated as "qualified." Work on or near exposed energized parts. a. b. Must be trained to distinguish exposed live parts from other parts of electrical equipment. Must be trained to determine the nominal voltage of exposed live parts. C. d. All of the above. Protect yourself from electrical hazards by: Leaving covers off of electrical panels to make inspection a. easier. Wearing specialized personal protective equipment as needed. Pulling fuses instead of locking out during repairs. d. Removing the ground prong from…arrow_forward
- 1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forwardschedules are typically provided to detail the circuits and overcurrent protection required for listribution equipment. Branch-circuit - Outlet C. d. ore distribution points for electrical in .... Switch Panelboardarrow_forward12.a. An electrical device would also fall into the classification of an electric(al)A. motor.B. load.C. component.D. fitting.12.b. A short circuit describes the condition where there's contact between theA. hot wire and the neutral wire.B. grounded conductor and the grounding wire.C. hot wire and the grounding wire.D. neutral wire and the grounded conductor.arrow_forward
- The term "____" is defined in NEC® Article 100 as "connected to establish electrical continuity and conductivity." Select one: A. BENDED (BENDING) B. BONDED (BONDING) C. SHUNTED (SHUNTING) D. GROUNDED (GROUNDING)arrow_forwardb) State six (6) examples of electrical hazard sources that can be found in home or office.arrow_forwardPart 2: Analysis and selection of the Wind Turbine. The team decides at install a 30 MW wind farm. The turbine that has been selected by the local contractor is an Enercon wind turbine. The specifications of all the available Enercon wind turbine is shown in the attached datasheet. 1. Decide on the required number of wind turbines needed. 2. In your own words, explain what the Betz limit for wind turbines means.arrow_forward
- Need help with second question if all that would be helpgularrow_forward12. Which of the following statements about ground faults is true?A. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.B. They usually occur between any grounded circuit conductor and the equipment grounding conductor.C. They can't result from human error.D. They're often normal and typically intentional.arrow_forward24. The National Electrical Code® _____ contains tables dealing with conductors for general wiring. Select one: A. 100 B. 110 C. 310 D. 300arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License