Textbook Question
Chapter 6, Problem 11R
Is a GFCI receptacle permitted be installed as a replacement in an old installation where the 2-wire circuit has no equipment grounding conductor? _________________
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5
When a three-conductor multi-wire circuit is used in place of two separate branch circuits to supply split-wired receptacles, the grounded (neutral) conductor is required to be ____.
A. durably markedB. pigtailed so that its continuity does not depend on the presence of a wiring deviceC. connected to the white or silver-colored receptacle binding screwD. both b and c
Equipment Grounding
13. A metal elbow is a part of a nonmetallic, underground raceway. The elbow won't need to be grounded as long as it's encased in at least _______ inches of concrete.
A. 4 B. 5 C. 2 D. 6
13 A. Which of the following can be in the form of a wire and is required to be installed with feeders and branch circuits?
A. Phased neutral conductorB. Equipment grounding conductor C. Grounded neutral conductorD. Grounding electrode conductor
Chapter 6 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 6 - Explain the operation of a ground-fault circuit...Ch. 6 - Prob. 2RCh. 6 - Where must GFCI receptacles be installed in...Ch. 6 - Prob. 4RCh. 6 - Prob. 5RCh. 6 - A homeowner calls in an electrical contractor to...Ch. 6 - Prob. 7RCh. 6 - Extremely long circuit runs connected to a GFCI...Ch. 6 - If a person comes in contact with the hot and...Ch. 6 - What might happen if the line and load connections...
Ch. 6 - Is a GFCI receptacle permitted be installed as a...Ch. 6 - Prob. 12RCh. 6 - Prob. 13RCh. 6 - Prob. 14RCh. 6 - Prob. 15RCh. 6 - Construction sites can be dangerous because of the...Ch. 6 - Prob. 17RCh. 6 - Prob. 18RCh. 6 - The term SPD is becoming quite common. What do the...Ch. 6 - Transients (surges) on a line can cause spikes or...Ch. 6 - Prob. 21RCh. 6 - Prob. 22RCh. 6 - Some line transients are not damaging to...Ch. 6 - Briefly explain the operation of an immersion...Ch. 6 - What range of leakage current must trip an IDCI?Ch. 6 - Prob. 26RCh. 6 - Other than for a few exceptions, the NEC requires...Ch. 6 - In an old house, an existing nongrounding...Ch. 6 - Prob. 29RCh. 6 - NEC 210.12(A) requires AFCI protection for the...Ch. 6 - When installing GFCI and AFCI circuit breakers in...Ch. 6 - Prob. 32RCh. 6 - Prob. 33RCh. 6 - A switch that is located inside a bedroom for an...Ch. 6 - Which of the following installations for a kitchen...Ch. 6 - The receptacle outlets in the garage are required...Ch. 6 - Two 125-volt receptacles on a 20-ampere, 120-volt...Ch. 6 - Prob. 38R
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
What is an uninitialized variable?
Starting Out with Programming Logic and Design (5th Edition) (What's New in Computer Science)
What are the design issues for character string types?
Concepts Of Programming Languages
How is the hydrodynamic entry length defined for flow in a pipe? Is the entry length longer in laminar or turbu...
Fluid Mechanics: Fundamentals and Applications
Assume a telephone signal travels through a cable at two-thirds the speed of light. How long does it take the s...
Electric Circuits. (11th Edition)
Why is the study of database technology important?
Database Concepts (8th Edition)
How are relationships between tables expressed in a relational database?
Modern Database Management
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardThe arrangement of grounding connections shall ensure that the disconnection or the removal of a luminaire, receptacle, or other device fed from the box does not interrupt the electrical continuity of the ____________ providing an effective ground-fault current path. grounding conductor(s) ungrounded conductor(s) equipment grounding conductor(s) all of these.arrow_forward7. If a grounded surface metal box makes direct contact with the mounting strap for a switch or receptacle,then theA. bonding jumper can be undersized.B. neutral conductor will operate as the equipment grounding conductor.C. bonding jumper isn't required.D. device must be protected with a GFCI device.arrow_forward
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forward11. Specific rules apply for the installation of _______, but no identification requirements for them exists.A. grounding electrode conductorsB. grounding electrodes.C. main bonding jumpers.D. equipment grounding conductors.arrow_forwardTerminals of switches and receptacles marked CO/ALR are suitable for use with _______________, _______________, and _______________ conductors.arrow_forward
- Please provide Handwritten answer Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.arrow_forward9. How is equipment containing ungrounded electrical systems required to be marked? A. With green wiresB. With a sign reading "Caution: Ungrounded System Operating at _______ Volts Between Conductors" C. With a red X D. With a sign reading "Danger: Do Not Touch Ungrounded System, Operating at _______ Volts"arrow_forward1._____ must not be installed beneath openings through which materials may be moved, such as openings in farm and commercial buildings, and must not be installed where they will obstruct entrance to these buildings. A. Overcurrent protection devices. B. Overhead-service conductors C. Grounding conductors D. Wiring systemsarrow_forward
- To testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forwardEquipment Grounding 10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.arrow_forwardA ____shall be used to connect the equipment grounding conductors, the service equipment enclosures, and where the system is grounded, the grounded service conductor to the grounding electrode. (a.) bus bar ( b.) 5/8” ground rod (c.) neutral conductor (d.) grounding electrode cond. For equipment rated 1200 amperes or more 600 volts or less, and over 6 feet wide, containing overcurrent devices, switching devices, or control devices, there shall be one entrance not less than ____inches wide and 6 ½ feet high at each end. (a.) 24 (b.) 36 (c.) 30 (d.) 48 When calculating the conductor fill for strut-type channel raceway with internal joiners, the raceway shall be permitted to be filled to _____% of the cross-sectional area. (a.) 20 ( c.) 30 (b.) 25 (d.) 40arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
How Thermistors Work - The Learning Circuit; Author: element14 presents;https://www.youtube.com/watch?v=g683mTSZ2i0;License: Standard Youtube License