Which of the following is true regarding the refrigerant piping on a rooftop package unit?
A. The discharge and liquid lines must be field installed.
B. The suction and liquid lines must be field installed.
C. The discharge and suction lines must be field installed.
D. No refrigerant lines are field installed.
The true statement regarding the refrigerant piping in a rooftop package unit.
Answer to Problem 1RQ
The true statement regarding the refrigerant piping in a rooftop package unit is No refrigerant lines are field installed.
Explanation of Solution
The rooftop package unit refers to a single housing which consist all the major components of the system. This package unit is assembled in the factory and charged in the factory. This unit is a complete package of the entire essential component required for the refrigeration or heat pump. It consists
- Condensers.
- Compressors.
- Metering devices.
- Evaporators.
These components are installed in the same cabin which is called rooftop package unit. Hence, there is no need for any refrigerant line. Therefore, after the installation of the entire component in a single unit there is no requirement to install the refrigeration line in the system. Hence, the fourth statement (no refrigerant lines are field installed) is true about the refrigerant piping in a rooftop package unit.
Conclusion:
The true statement regarding the refrigerant piping in a rooftop package unit is No refrigerant lines are field installed.
Want to see more full solutions like this?
Chapter 50 Solutions
Bundle: Refrigeration And Air Conditioning Technology, 8th + Lab Manual + Lms Integrated For Mindtap Hvac-r, 4 Terms (24 Months) Printed Access Card
- Can you answer this question?arrow_forwardCan you answer this question?arrow_forwardA gear has a gear wheel with 16 teeth. The gear should be dimensioned for the highest and lowest gear ratio. Looking for output power, torque, speed?nin= 2000 rpmmin = 30Nmn=0,9a max= 450 mmModule 4Gear limitsz1 z213 13-1614 14-2615 15-4516 16-10117 17-131418 18-…..I have calculate but I can’t get the right answers…..√16 =459x60/56x57=1.1 lowest59x60/13x13=20,94 highestnut=2000/1.1= 1818rpmnut=2000/20.94=95.5 rpmMut=1.1x30=33 NmMut=20.94x30=628,2 Nm(Right answer)LowestZ=13, M=24,4Nm, n=2462 rpmHighestZ=92, M=172,5Nm, n=347,8 rpmP=5655W on botharrow_forward
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning