Textbook Question
Chapter 5, Problem 7RQ
An 11-pin control relay contains three sets of single-pole double throw contacts. List the pin numbers by pairs that can be used as normally open contacts.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Q1
Boxes (or certain production parts) are moved by a double-acting cylinder away from a gravity-feed magazine towards an assembly device. A push button and a pedal switch are to be incorporated in the circuit. The cylinder is to move out when either of these is actuated. The return stroke is actuated by the cylinder rod after it reaches the end of the forward stroke.
Draw the pneumatic circuit diagram using ISO symbols and connecting the ports with solid lines.
All terminals have a defined wire size range. If I had a wire of 2.0mm / 15 AWG, what terminal should I use?
A. Red insulated terminal.
B. Blue insulated terminal.
C. Yellow insulated terminal.
D. It doesn’t matter as all these answers are correct.
Chapter 5 Solutions
Understanding Motor Controls
Ch. 5 - Prob. 1RQCh. 5 - Prob. 2RQCh. 5 - Explain the difference between auxiliary contacts...Ch. 5 - Prob. 4RQCh. 5 - What is optoisolation and what is its main...Ch. 5 - What pin numbers are connected to the coil of an...Ch. 5 - An 11-pin control relay contains three sets of...Ch. 5 - What is the purpose of the shading coil?
Ch. 5 - Refer to the circuit shown in Figure 5-29. Is the...Ch. 5 - What is the difference between a motor starter and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What pin numbers are connected to the coil of an 8-pin control relay?arrow_forwardHow does the National Electrical Code specify that the high leg of a four-wire delta connection be marked?arrow_forwardRefer to Figure 21–1 to answer the following questions. When switch HOA SW 122 is in the off position, which contacts have connection between them?arrow_forward
- Power-consuming devices are wired in _____(series orparallel).arrow_forwardIf the load in question 7 was supplied by two autotransformers connected in open delta, what would be the minimum standard size transformers that could be used to supply this load?arrow_forwardRefer to the schematic in Figure 7-10. Assume that when the START button is pressed, the control transformer fuse blows. What is the most likely cause of this trouble? Figure 7-10 Numbers are placed beside all components.arrow_forward
- Refer to the circuit shown in Figure 7-10. If wire number 11 were disconnected at the normally open auxiliary M contact, how would the circuit operate? Figure 7-10 Numbers are placed beside all components.arrow_forwardExplain the difference between auxiliary contacts and load contacts.arrow_forwardWhat is the Relay Number and its law?arrow_forward
- A 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardRefer to the circuit shown in Figure 5-29. In this circuit, the HR contactor is equipped with five contacts. Three are load contacts and two are auxiliary contacts. From looking at the schematic diagram, how is it possible to identify which contacts are the load contacts and which are the auxiliary contacts? Figure 5-29 The contactor contains both load and auxiliary contacts.arrow_forwardReferring to the schematic shown in Figure 97, how would the circuit operate if the normally closed R contact connected in series with F coil were to be connected normally open?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781305498129Author:Stephen L. HermanPublisher:Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781305498129
Author:Stephen L. Herman
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Hand Tools; Author: UCI Media;https://www.youtube.com/watch?v=4o0tqF0jDdo;License: Standard Youtube License