Four-way switches must be wired __________ in a switching circuit that has more than two switching locations.
Select one:
A. IN LINE WITH THE THREE-WAY SWITCHES
B. AFTER THE THREE-WAY SWITCHES
C. BEFORE THE THREE-WAY SWITCHES
D. BETWEEN THE THREE-WAY SWITCHES
The National Electrical Code® requires that all switching be done in the __________ circuit conductor.
Select one:
A. GROUNDED
B. SWITCH LOOP
C. GROUNDING
D. UNGROUNDED
12. A short circuit describes the condition where there's contact between theA. hot wire and the neutral wire.B. grounded conductor and the grounding wire.C. hot wire and the grounding wire.D. neutral wire and the grounded conductor.
I'm not sure if it's the letter A or C, could you help me with the correct answer.
Chapter 5 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 5 - The identified grounded circuit conductor must be...Ch. 5 - Explain how lighting switches are rated.Ch. 5 - Prob. 4RCh. 5 - Prob. 5RCh. 5 - To control a lighting load from one control point,...Ch. 5 - Prob. 7RCh. 5 - Complete the connections in the following...Ch. 5 - Complete the connections for the diagram....Ch. 5 - A three-way switch may be compared to a _____...Ch. 5 - Prob. 11R
Ch. 5 - Complete the connections in the following...Ch. 5 - When connecting 4-way switches, care must be taken...Ch. 5 - Show the connections for a ceiling outlet that is...Ch. 5 - Match the following switch types with the correct...Ch. 5 - When connecting single-pole, 3-way, and 4-way...Ch. 5 - What section of the Code emphasizes the fact that...Ch. 5 - If you had to install an underground 3-wire feeder...Ch. 5 - Is it always necessary to attach the bare...Ch. 5 - List the methods by which an equipment grounding...Ch. 5 - When two nonmetallic-sheathed cables (Type NM-B)...Ch. 5 - Define an equipment grounding conductor.Ch. 5 - When metal toggle switchplates are used with...Ch. 5 - Does the Code permit the ampacity of switch legs...Ch. 5 - Prob. 26RCh. 5 - Prob. 27R
Knowledge Booster
Similar questions
- The wording that I am running into with questions such as "The number of conductors required to be installed between three-way and four-way switches is " is confusing. The text is not expalining this in a way that I am understanding anything other than grounding conductor, which is optional unless I am using a metal box. So what type of "conductor" is beng discussed?arrow_forwardQUESTION 3 Pair up the correct descriptions with the codes written in Sketch for Arduino : void setup () A. Run setup and set pin 13 to be an output B. Run loop repetitively C. Set pin 13 to high (LED on) D. Delay for half a second, and then Set pin 13 to low (LED off) pinMode (13, OUTPUT): E, Delay for a full second : Void loop 0 F. Complete one iteration of the loop, and run it again G. Delay for 500 seconds, and then Set pin 13 to low (LED of) H. Run loop once : digitalWrite (13, HIGH): edelay (500): digitalWrite (13, LOW): delay (1000);arrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forward
- All cut ends of conduits shall be reamed or otherwise finished to remove rough edges. Where conduit is threaded in the field, a standard cutting die with a ____ -in. taper per ft (1 in 16) shall be used. Select one: A. 3/8 B. 1/2 C. 1 D. 3/4arrow_forwardWhat assumptions can you make regarding the following receptacle wiring? Check all that apply. White neutral wire Grounding screw Brass screw terminal Silver screw terminal Black hot wire Red hot wire Grounding wires Grounding screw terminal O device is at end-of-run device box does not need a ground connection this is a split-circuit receptacle neutral side receptacle tab must be removedarrow_forwardA shunt device that remains connected to the meter movement and thereby eliminates contact resistance problems is the_______ shunt.arrow_forward
- What code sets stabdard for the electrical installation work?arrow_forward3.a. When a device is removed from an outlet box, the_______ wire must be connected in such a way that maintains continuity. A. neutral B. grounding C. hot D. grounded neutral 3. To correctly saw a lath and plaster wall, point the teeth of the saw A. away from you and cut on the pushing stroke. B. away from you and cut on the pulling stroke. C. toward you and cut on the pushing stroke. D. toward you and cut on the pulling stroke.arrow_forward4.A. The insulation color of a grounded wire should beA. white.B. red.C. black. 4.B. A switch is always installed in a circuit so that it's connected to theA. grounding wire.B. ungrounded conductor.C. neutral wire.arrow_forward
- Electrical plants Define the terms "Main column ." " Line ." " Protection earth " and " Operating eartharrow_forwardQOD Is it allowed by code to run 120 volt circuits in the same raceway as 480 volt circuits?arrow_forwardQuestion 6 B Thevenin’s Theorem RL what VTH RTH Full explain this question very fast solution sent me step by step Not:- Text typing work only and Don't ignore any part all part work uarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning