FUNDAMENTALS OF THERMODYNAMICS
10th Edition
ISBN: 9781119634928
Author: Borgnakke
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
A water cooler for drinking water should cool 25 L/h water from 18 C to 10 C while the water reservoirs also gains 60 W from heat transfer. Assume that a small refrigeration unit with a COP of 2.5 does the cooling. Find the power input to the unit.
A solar collector absorbed 40W/m2 heat from the atmosphere. This is equal to the convection brought by air for drying purpose. If the temperature of the air is 40C while the solar collector area's temperature is 80C and neglecting effect of radiation, find the convective heat transfer coefficient.
Q.7
The COP of the heat pump is found to be
5.62, and the heat pump operates with the
source at 25°C, while the heat absorbed
is 2.12 kW. What is the amount of heat
rejected ?
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- I need the answer as soon as possiblearrow_forwardFor a power system operates with Wcycle = 810 BTU and Qout = 1769 BTU. What is the thermal efficiency?arrow_forwardA bio-reactor is kept at 42°C by a heat pump driven by a motor of 2 kW. The reactor loses energy at a rate of 0.5 kW per degree difference to the colder ambient. The heat pump has a COP that is 50% that of a Carnot heat pump. What is the minimum ambient temperature for which the heat pump is sufficient?arrow_forward
- 3.0 A cold storage is to be maintained at -5°C while the surroundings are at 35°C. The heat leakage from the surroundings into the cold storage is estimated to be 28 kW. The actual C.O.P. of the refrigeration plant used is one fourth that of an ideal plant working between the same temperatures. Find the power required to drive the plant.arrow_forward3.0 A cold storage is to be maintained at -5°C while the surroundings are at 35°C. The heat leakage from the surroundings into the cold storage is estimated to be 30 kw. The actual C.O.P. of the refrigeration plant used is one third that of an ideal plant working between the same temperatures. Find the power required to drive the plant.arrow_forwardA heat engine of 30% efficiency drives a heat pump of COP 5. The heat is transferred both from engine and the heat pump to circulating water for heating the building in winter. Find the ratio of heat transfer to the circulating water from heat pump to the heat transfer to the circulating water from the heatarrow_forward
- A 4-kW heat pump is operated by a peasant. It should keep a duck hatchery at 32 degrees Celsius, where heat is removed at a rate of 10 kW to the cooler ambient Tambiont. What is the minimum COP for the pump that will be acceptable?arrow_forwardI need the answer as soon as possiblearrow_forwardA refrigerator should remove 400 kJ from some food. Assume the refrigerator works in a Carnot between -15 C and 45 C with a motor compressor of 400 W. How much time does it take if this is the only cooling loadarrow_forward
- Don't copy from any sourcearrow_forwardA heat pump shown is driven by 2.5 MW motor and receives heat from a source at 80 C and deliver energy to a boiler that operates at constant pressure and saturation temperature of 130 C. The water enters the boiler as saturated liquid and leaves as saturated vapor at the same temperature. The heat pump operates with a COP (coefficient of performance) that is 70% of a Carnot heat pump COP. Find: 1- the maximum mass flow rate of water the system can deliver 2- the heat received from the cold source Q, boiler mwater eb TH V HP 2.5 MW TL=80°Carrow_forwardThe heat loss from a chicken coop (chicken house) is K(Tnside - Totside) during the winter, where K is 1.5 kW/K. The chicken coop temperature can vary between 15 °C and 25 °C without harming egg production. A heat pump with a coefficient of performance of 40% of that of a reversible heat pump is used to heat the chicken coop. What are the minimum power requirements if the outside temperature is -5 °C? .arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Thermodynamic Availability, What is?; Author: MechanicaLEi;https://www.youtube.com/watch?v=-04oxjgS99w;License: Standard Youtube License