FUNDAMENTALS OF THERMODYNAMICS
10th Edition
ISBN: 9781119634928
Author: Borgnakke
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
The heat loss from a chicken coop (chicken house) is K(Tnside - Totside) during the winter, where K
is 1.5 kW/K. The chicken coop temperature can vary between 15 °C and 25 °C without harming
egg production. A heat pump with a coefficient of performance of 40% of that of a reversible heat
pump is used to heat the chicken coop. What are the minimum power requirements if the outside
temperature is -5 °C? .
On a cold day, a homeowner uses a heat pump to absorb heat from the outside air at 15oF and transfers it into his home at a temperature of 29.4oC. What is the COP of his heat pump?
A building is being heated through the help of a Carnot heat pump and is required to be maintained at 20 degrees C always. When the temp outside drops to -10 degrees C, the rate at which heat is lost from the building is 25kW. What is the minimum electrical power required (kW) in order to drive the heat pump?
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Answers are included, but I need the work.arrow_forwardof Performance of the heat pump which should be higher than 100%) when the cabin temperature is 24°C and there is a 20°C temperature difference betveen the indoor cabin and outside at night?arrow_forwardOne of the Computer company in the US uses carnot heat pump to be used for heating its office and maintaining it at 230C during the winter.. The average outdoor temp outside office is 30C. The office is estimated to lose heat at a steady rate of 27600 kw.arrow_forward
- A 4-kW heat pump is operated by a peasant. It should keep a duck hatchery at 32 degrees Celsius, where heat is removed at a rate of 10 kW to the cooler ambient Tambiont. What is the minimum COP for the pump that will be acceptable?arrow_forwardI need the answer as soon as possiblearrow_forwardA carnet heat engine receives heat from a hot reservoir of a temperature 327°c and it rejects the heat to an enviroment with an atmospheric temperature of 27°c . The entire work output of the heat engine is used to run a refrigerator which transfers heat from freezing compartment with a temperature of -23°c and rehects the heat to the same enviroment . Cooling rate required by the refrigirator is 4.5 kW. A) if the rate of heat transfer from hot reservoir to the heat engine is 0.90 kW . Predict the minimum additional power required to run the refrigerator . B) predict a minimum rate of heat transfer from hot reservoir to the heat engine required in order to run the refrigerator without any additional powerarrow_forward
- Need asaparrow_forwardDetermine the power consumption of a domestic refrigerator if its refrigerat- ing capacity is TR. It is operating in an ambient of 40°C. Temperature in 8 the freezer must be maintained at –15°C. COP of the system is half the Carnot COP. Assume suitable condensing and evaporating temperatures.arrow_forwardSince Lucas is an engineer familiar with thermodynamics. He decided to create his own heat engine at home to avoid paying for electricity. He created a small, makeshift heat engine for trial. The combustion of his fuel. diesel, reaches a temperature of 750°C, while waste heat is disposed to the atmosphere at 50°C. He, then connected a generator and a heat pump to the heat engine to check the amount of power being produced. Assume that the heat pump will be used to warm his room to 25°C, while the outside temperature is at 5°C. Lucas' rooms loses 85,000 kJ/hr of heat. And, 25% of the heat engine's power output goes to the heat pump. How much diesel (in kg) needs to be burned by the heat engine to maintain the temperature in Lucas' room? Assume carnot heat engine and heat pump. If the natural gas has a heating value of 22,000 BTU/lb.arrow_forward
- Asking second time , Strictly don't use chatgpt. I need to understand the concept,give detailed solution in Handwritten format.arrow_forwardTwo Carnot heat engines operate in series. The first heat engine absorbs heat of 100kW at 400°C while second heat engine rejects heat at 100°C. If the efficiencies of the heat engines are the same,a. Draw the schematic diagram of the systemb. Find the intermediate temperature in between the heat enginesc. Heat rejected for both heat enginesarrow_forwardcan you please solve this for me (the fraction of steam extracted from theturbine for the open feedwater heater)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY