Industrial Motor Control
7th Edition
ISBN: 9781133691808
Author: Stephen Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 47, Problem 12RQ
To determine
The size of the conductor that should be used to supply all the motors when the 5 horsepower, three phase motor with the NEMA code B is connected to the 240 V line, the conductor are copper with type THWN insulation.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A (21 HP, 3-Phase, 380 volts) motor with an efficiency of 95% is operating at a load
factor of 0.63. What is the input current (Amperes) when the power factor is 89%? (1
HP = 0.75 kW)
A 20 HP, DC motor is connected to a 500-volt DC line. What is the full load running current of this motor?
A transformer has a primary voltage of 480 volts and a secondary voltage of 20 volts. What is the turns ratio of the transformer?
Chapter 47 Solutions
Industrial Motor Control
Knowledge Booster
Similar questions
- A large motor has a full load current rating of 425 amperes. Current transformers with a ratio of 600:5 are used to reduce the current to the overload heaters. What should be the full load current rating of the overload heaters?arrow_forwardTwo transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardHow many transformers are needed to make an open-delta connection?arrow_forward
- A 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardA 125-hp synchronous motor is connected to a 230-volt three-phase AC line. The motor is intended to operate at 80% power factor. What is the full-load running current of this motor? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forward
- Assume that a line voltage of 2400 volts is connected to the primary of the three-phase transformer and the line voltage of the secondary is 240 volts. What is the turns ratio of the transformer?arrow_forwardEx: A single phase 50 KVA transformer has primary voltage of 6600 v and secondary voltage of 254 v and has 32 secondary turns. Calculate the number of primary turns and primary and secondary currents.arrow_forwardQ A motor of 15 horsepower, has a code letter L, and is operated on a 400-volt line. Find the locked rotor currentarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning