Question
Chapter 4, Problem 41R
To determine
Whether separate equipment grounding conductor is needed to be installed to a ground air-conditioner.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A means shall be provided in each metal box over 100 cubic inches for the connection of an equipment grounding conductor. The means shall be permitted to be ______.
a tapped hole
the cover screw
III. a screw used to mount the box
(a.) I only (c.) I & II only (b.) II only (d.) I, II or III
1.a. Section 300.15(C) requires a fitting to be installed on each end of a conduit or tubing being used toprovide support or protection to protect the cable fromA. hazardous vapors.B. direct sunlight.C. abrasion.D. extreme heat or cold.1.b. Typically, a/an _______ is a better electrode than a ground rod because it provides a greater surface areafrom which the electrons can be dissipated.A. continuous grounding conductorB. clamp-on ground resistance meterC. rebarD. OCPD
4.a. The ___ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total
4.b. What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight
4.c. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.
Chapter 4 Solutions
ELECTRICAL WIRING:RESIDENTAL-6 PLANS
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forwardWhat is the 277-volt–single-phase–60-hertz system used for? Select one: A. RECEPTACLE BRANCH CIRCUITS B. LIGHTING BRANCH CIRCUITS C. MOTOR BRANCH CIRCUITS D. RESIDENTIAL BRANCH CIRCUITSarrow_forward
- An emergency system shall have adequate capacity and rating for _______ to be operated simultaneously A. 80% of the loads B. All loads C. 125% of the loads D. None of these answersarrow_forwardFill in the blank 14. Mechanisms for __________ include switches,sensors,and circuitry.arrow_forwardTo testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forward
- Equipment Grounding 10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.arrow_forward45. A switch or circuit breaker can be used as both the controller and disconnecting means if it a. opens all ungrounded conductors as required by NEC 430.103 b. is protected by an overcurrent device in each ungrounded conductor c. is manually operable, or both power and manually operable d. All of these answersarrow_forward1-Calculate the minimum and maximum protection for an A/C, its conductors(75 °C) and its grounding. For the following values: 1- FLC compressor = 30 A 2- FLC condenser = 3 A NEC LOOP CONDUCTORS 440.33 440.34 CONDUCTORS 440.32 OCPDS 440.22(A) 440.35 OCPD 440.22(A) +440.22(B) OVERLOADS 440.52(A(1) DISCONNECT 440.14 DISCONNECTING MEANS 440.14 •SEE Ex 1 TO 440.14 A/C UNIT WITH SINGLE COMPRESSOR CONDUCTORS 440.32 440.33 CONDUCTORS 440.32 440.33arrow_forward
- Messages AA Statement one Training will allow you to safely erect a mobile. tower scaffold on any ground surface condition. and access the tower both internal and externally Statement two In windy conditions placing sheeting around the mobile tower scaffold will protect the workers on the tower a) Statement two is incorrect b) Statement one and two are correct c) Statement one is correct and statement two is incorrect d) Both statements are incorrect actclass.co.uk 22 Questi 23 Questi 24 Questi 25 Questi 26 Questi Submit Answers Ćarrow_forwardThe NEC requires that each service-disconnecting means be suitable for A. the prevailing conditions.B. disconnecting the meter.C. wet conditions. D. hazardous locations.arrow_forward5. An automatic switch or cutout is allowed in the equipment grounding conductor circuit when A. there's a redundant equipment grounding conductor in the circuit. B. the power sources are disconnected when operated. C. it's bonded around the disconnecting device. D. it also opens the neutral.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning