Question
Chapter 4, Problem 4.11QAP
Interpretation Introduction
(a)
Interpretation:
The conversion rate for baseline to baseline time of
Concept introduction:
Conversion rate: It can be defined as number of samples taken per second to convert an analog signal to digital signal.
Interpretation Introduction
(b)
Interpretation:
The conversion rate for baseline to baseline time of
Concept introduction:
Conversion rate: It can be defined as number of samples taken per second to convert an analog signal to digital signal.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The options are larger or smaller.
An internal standard is incorporated into an analysis method when systematic sources of variation (i.e., variation not under statistical control) exist that cannot be eliminated. A sample must be injected into the chromatographic system in order for it to be analyzed using HPLC. Which type of injection mode would create the largest source of systematic variation? automated sample injector manual sample injector
Which of the following statements about a gas chromatogram is correct?
O The height of the peak in the gas chromatogram is proportional to the amount of the compound present in the sample.
Tailing indicates that the gas chromatograph has been overloaded.
O If the peaks are broad this could indicate that the sample is too polar.
O If the peaks overlap, the temperature can be increased at a slower rate to improve resolution.
O The retention time can be used to identify a compound by comparison with literature values, regardless of the conditions used.
Knowledge Booster
Similar questions
- One method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forwardWhich statement(s) are correct for gas chromatography? A) the components in a mixture can be identified from their retention time. B) the relative peak areas give the proportions of components in a mixture. C) Calibration curves are used to confirms the concentrations of components in a mixture.arrow_forwardWhat is the purpose of adding two drops of acetic acid in thin layer chromatography of plant pigment? What would be the effect of the following errors in chromatographic work? - a) The solvent level in the developing chamber is higher than the spotted sample. - b) Too much sample is applied to the paper. - c) The paper is allowed to remain in the chamber after the solvent front has reached the top of the plate.arrow_forward
- The internal standard method compensates for errors that affect both the analyte and the reference. True Falsearrow_forward24 4 5 11 4. 16 19 12 21 15 3 6 8 9 10 23 2 13 14 17 18 20 22 2 4 6. 10 12 14 16 18 20 22 26 Time (min) What is the estimated time of the entire chromatographic run? 24 minutes 25 minutes 26 minutes cannot be determined from the given 24arrow_forwardConsider the peaks for heptane (14.56 min) and p-difluorobenzene (14.77 min) in the chromatogram. The column is 30.0 m long. (a) Measure w1/2 for each peak and calculate the number of plates and the plate height for each. (b) From w1/2, compute w for each peak and find the resolution between the two peaks.arrow_forward
- Internal standard (As , Cs ), analyte with known concentration (Ax , Cx ) In a chromatographic equipment, a solution containing 0.006727 X and 0.008331 M S give peak area of Ax= 2316 and As= 207. To analyze an unknown sample, 5.0mL of 0.008331M S was added to 5.0mL of X, and the mixture was diluted to 50.0mL. This mixture gave a chromatography spectrum with area Ax= 3206 and As= 200. Find Cx.arrow_forwardThe plot of retention time versus detector signal in chromatography called?arrow_forwardThe response of the instrument must be lincar in the sample matrix. Systematic errors can occur due to sample or standard preparation. It consists of a series of standard analyte solutions separate from the unknown. A blank is used to correct the response from the instrument. Known quantities of a standard solution of the analyte are added to the unknown. It is the method of choice when the matrix of the sample may affect the signal. Matrix effects can cause the same analyte concentration in an unknown and standard to give different responses. It is used to measure the instrument response as a function of a known analyte concentration under a set of conditions.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemical Principles in the LaboratoryChemistryISBN:9781305264434Author:Emil Slowinski, Wayne C. Wolsey, Robert RossiPublisher:Brooks Cole
- Macroscale and Microscale Organic ExperimentsChemistryISBN:9781305577190Author:Kenneth L. Williamson, Katherine M. MastersPublisher:Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemical Principles in the Laboratory
Chemistry
ISBN:9781305264434
Author:Emil Slowinski, Wayne C. Wolsey, Robert Rossi
Publisher:Brooks Cole
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Brooks Cole