Concept explainers
The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size ⅜ flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________
Trending nowThis is a popular solution!
Chapter 4 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Additional Engineering Textbook Solutions
Modern Database Management
Elementary Surveying: An Introduction To Geomatics (15th Edition)
Java: An Introduction to Problem Solving and Programming (8th Edition)
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
Vector Mechanics for Engineers: Statics and Dynamics
Database Concepts (8th Edition)
- QUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forwardL1. Boxes are classified by type, construction, andA. installation location.B. luminaire support capability.C. number of knockouts.D. power rating L2. Which of the following devices must be placed at each end of an armored cable to prevent damage tothe conductors?A. An insulating sliderB. An insertion couplingC. An antishort bushingD. A metal loop fitting L3. Which of the following is the maximum cross-sectional conductor fill area for underfloor raceways?A. 50%B. 60%C. 40%D. 30%arrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forwardQUESTION 8 We are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation.arrow_forwardHow many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forward
- Assignment on Threaded jointsDue date:__________________ ___________________ ________________ Surname Given names IDA power line tower is erected to support a high-voltage power line (see figure below),which includes six phase conductors and three Earth shield wires. The tower isfabricated as a steel structure resting on four square supporting feet bolted to aconcrete foundation with four Anker bolts at each support (see figure below). Theresultant tension force FT from cables on each side of the tower is applied at point m,and can be at 60o to the horizontal plane (sagging downwards) if the tower is installedon a plane or at 30o to the horizontal plane pointed upwards if the tower is installed on ahilly landscape. The gusty wind load, which could be represented with a resultant forceof Fw is applied at the geometric centre of the tower n in any direction in the horizontalplane (see figure below) and tends to shift the tower sideways and topple it. In the caseof an accident when all…arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forward26. Armored cable used to connect recessed luminaries or equipment within an accessible ceiling can be unsecured for lengths up to a. 2 ft. b. 3 ft. C. 4 ½ ft. d. 6 ft.arrow_forward
- 8. Connect the Electronic VOM, set to the ammeter function on the 15mAdc range,between points A and D.9. Close switch S1. Measure current IAB. IAB = 19.5 mAdc 10. Measure current IAD flowing through resistor R1. IAD = 14.8 mAdcAre currents IAB and IAD entering or leaving point A? __________ Is the sum of currents IAB and IAD equal to total current IT? __________Is the current IAB entering or leaving a junction point B? __________arrow_forward2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forwardQUESTION 5 A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle? a It must be secured by at least two screws. b The single 6/32 screw holding it in the cover must be tight. c It must be secured directly to the 4 inch square box. d It is not permitted to be installed in raised covers.arrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT