A 6-mm-thick stainless steel strip (k = 21 W/m .K, p = 8000 kg/m 3 , a n d c p = 570 J/kg .K) and exiting an oven at a temperature of 500°C is allowed to cool within a buffer zone distance of 5 m. To prevent thermal bums to workers who are handling the strip at the end of the buffer zone, the surface temperature of the strip should be cooled to 45°C. If the air temperature in the butler zone is 15°C and the convection heat transfer coefficient is 120 W/m 2 K, determine the maximum speed of the stainless steel strip.
A 6-mm-thick stainless steel strip (k = 21 W/m .K, p = 8000 kg/m 3 , a n d c p = 570 J/kg .K) and exiting an oven at a temperature of 500°C is allowed to cool within a buffer zone distance of 5 m. To prevent thermal bums to workers who are handling the strip at the end of the buffer zone, the surface temperature of the strip should be cooled to 45°C. If the air temperature in the butler zone is 15°C and the convection heat transfer coefficient is 120 W/m 2 K, determine the maximum speed of the stainless steel strip.
Solution Summary: The author calculates the temperature of stainless steel strip after time t for transient heat transfer rate.
A 6-mm-thick stainless steel strip
(k = 21 W/m
.K,
p
=
8000
kg/m
3
,
a
n
d
c
p
=
570
J/kg
.K)
and exiting an oven at a temperature of 500°C is allowed to cool within a buffer zone distance of 5 m. To prevent thermal bums to workers who are handling the strip at the end of the buffer zone, the surface temperature of the strip should be cooled to 45°C. If the air temperature in the butler zone is 15°C and the convection heat transfer coefficient is 120 W/m2 K, determine the maximum speed of the stainless steel strip.
Can you provide steps and an explaination on how the height value to calculate the Pressure at point B is (-5-3.5) and the solution is 86.4kPa.
PROBLEM 3.46
The solid cylindrical rod BC of length L = 600
mm is attached to the rigid lever AB of length a
= 380 mm and to the support at C. When a 500
N force P is applied at A, design specifications
require that the displacement of A not exceed
25 mm when a 500 N force P is applied at A
For the material indicated determine the
required diameter of the rod.
Aluminium: Tall = 65 MPa, G = 27 GPa.
A
Find the equivalent mass of the rocker arm assembly with respect to the x coordinate.