Question
Chapter 31, Problem 5R
To determine
Choose the correct option among the given choices to find the minimum bending radius that is recommended while installing Category-5 rated cables.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
What is the super tension cable and application,rating
The characteristics of conductor material are (is):
a. High tensile strength.
b. High electrical conductivity.
c. Low cost.
d. All of the above.
1. The choice of conductor material will depend upon the
and ..........
2. copper conductor used in the ......... form as standard
******
conductor.
3. We can used the Galvanized steel conductor for ........ or for
4. The wooden poles used in rural areas because it is
5. The holes in RCC used to
and........
6. Porcelain used as a good insulator and it mixture of ...
……......
and
7. Strain insulator used when there is a ......... or...
8. Because the shunt capacitor the ....... is not same through the
dises and the efficiency will .........
9. In Stormy weather, the ...... that make corona occurs at much
less voltage compared to the fair weather.
10. String insulator with 4 units, 33.33% on the bottom most one.
The string efficiency is ........
11......... is the type of insulator used for holding the HV
overhead conductor on the straight running poles.
12.......... possess no free-charge carriers and thus are non-
conductive.
13. Corona accompanied by .......
.....
Chapter 31 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What is the voltage rating of the conductors in Type NMC cable? _______________arrow_forwardThe Aluminum Electrical Conductor Handbook lists a dc resistance of 0.01558 ohm per 1000 ft at 20C and a 60-Hz resistance of 0.0956 ohm per mile at 50C for the all-aluminum Marigold conductor, which has 61 strands and whose size is 1113 kcmil. Assuming an increase in resistance of 2 for spiraling, calculate and verify the dc resistance. Then calculate the dc resistance at 50C, and determine the percentage increase due to skin effect.arrow_forwardExplain the concept of cable bending radius and why it is critical for cable installations. Provide examples of situations where this becomes crucial.arrow_forward
- A two wire DC distributor AB, 1000 meter long, is supplied from both ends, 240 V at A and 242 V at B. There is a concentrated load of 200 A at a distance of 400 meter from A and a uniformly load 1.0 A/m between the midpoint and end B. Determine (i) the current fed at points A and B (ii) the point of minimum potential and (iii) voltage and this point. Consider cable resistance as 0.005 ohm per 1000 meter each core.arrow_forwardDescribe the construction and symbol of semi conductor devicearrow_forwardA DC is supplied through a solid conductor cable. The fault in the cable can be determined by using Murray Loop Test. The healthy cable has the insulation resistance of 1 kilo Ohms per meter. No fault occurred till the first 10 km. The core of healthy cable has the circumference of 7.86cm. If the resistivity of insulation is 900 G Ohm-mm, what is the diameter of the cable.arrow_forward
- 3. A two conductor main A B, 500 m in length is fed from both ends at 250 volts. Loads of 50 A, 60 A, 40 A and 30 A are tapped at distance of 100 m, 250 m, 350 m and 400 m from end A respectively. If the X- section of conductor be 1 cm and specific resistance of the material of the conductor is 1-7 u 2 cm, determine the minimum consumer voltage.arrow_forwardLabel the parts of Tubular Steel Polesarrow_forwardWhich among these statements is false or incorrect? O A. The bigger the value of the Breaking Stress, the longer the Sag. O B. The bigger the Safety Factor used, the longer the Sag. O C. The older the conductor, the longer the Sag. O D. The heavier the weight per unit length, the longer the Sag.arrow_forward
- Please solve this question all section handwritten step-by-step solutions to make me understand well thank youarrow_forwardWhat are the limitations of solid type cables? How are these overcome in pressure cables?arrow_forwardb. traveler (ti)*) D. Several factors or conditions can cause conductors to overheat, but often overlooked is the possibility A a. induction heating b. ambient temperature C. the size of conductors d. groundingarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License