Question
Chapter 30, Problem 10R
To determine
Mention how the receptacles must be protected which is placed within 20 ft inside the swimming pool wall.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
QUESTION 5
A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle?
a
It must be secured by at least two screws.
b
The single 6/32 screw holding it in the cover must be tight.
c
It must be secured directly to the 4 inch square box.
d
It is not permitted to be installed in raised covers.
QUESTION 8
Enclosures that are not over 100 cubic inches in size and which have two conduits supported within three feet on either side of the enclosure and the enclosure does not contain devices or support fixtures shall not be required to have the enclosure supported if the conduits are _____.
a
installed with locknuts inside and outside enclosure
b
shoulders of fittings outside and locknuts inside the box
c
rigid nonmetallic conduits
d
threaded into hubs identified for the purpose
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
Chapter 30 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Question 17 The electrode and circuit must provide a flow path to the earth with less than of resistance. 5 10 25 30 Question 18 A(n) is a permanent conductor placed across a water meter to provide a continuous flow path for ground current. shunt bare conductor electrode bonding conductorarrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward___________ is an Area on a device characteristic where the ratio between applied voltage and resulting current is constant.arrow_forward
- 13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5arrow_forwardFor the 25ft tap rule the __________ of the smaller conductors must be not less than one third of the rating of the upstream over current protective devicesarrow_forwardQuestion 6 B Thevenin’s Theorem RL what VTH RTH Full explain this question very fast solution sent me step by step Not:- Text typing work only and Don't ignore any part all part work uarrow_forward
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardA branch circuit consists of five (5) convenience outlets. Determine the size of the conductor to be usedto the said branch circuit. Please indicate the type of conductors to be usedarrow_forwardA means shall be provided in each metal box over 100 cubic inches for the connection of an equipment grounding conductor. The means shall be permitted to be ______. a tapped hole the cover screw III. a screw used to mount the box (a.) I only (c.) I & II only (b.) II only (d.) I, II or IIIarrow_forward
- Article 300 cable or nonmetallic raceway-type wiring methods installed in a groove, to be covered by wallboard, siding paneling, carpeting, or similar finish must be protected by 1/16in.thick____ or by not less than 1 1/4in. of free space for the full length of the groove. A thinner plate that provides equal or better protection may be used if listed and marked. a. steel plate b. steel sleeve c. PVC bushing d. a or barrow_forwardTo testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT