Electrical Wiring Residential
19th Edition
ISBN: 9781337101837
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 3, Problem 34R
To determine
Explain how the wall receptacle outlets are related to the receptacle’s position near the sliding glass door.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
Answer the following:
A) Type of clipper circuit per level of clipping.
1. ___________
2. ___________
3. ___________
B) Type of clipper circuit per non-linear devices used.
1. ___________
2. ___________
C) Other term for clipper circuit.
1. ___________
2. ___________
3. ___________
Chapter 3 Solutions
Electrical Wiring Residential
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardQUESTION 5 A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle? a It must be secured by at least two screws. b The single 6/32 screw holding it in the cover must be tight. c It must be secured directly to the 4 inch square box. d It is not permitted to be installed in raised covers.arrow_forwardAn open in one of the heated rear window grid elements can be repaired by ______. a. pealing the heat grid off the glass with a heat gun and installing a new grid element b. applying a thin strip of a repair compound to the damaged area c. bridging the damaged area with rosin core solder d. replacing the window glassarrow_forward
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardWhen used as service equipment, a panelboard (load center) must be ______________________ that is suitable for use as service equipment, 230.66. If the panelboard (load center) contains the main service disconnect, it must be clearly marked ____________________________________, 230.70(B).arrow_forwardDetermine the proper size of copper wire conductor necessary to apply a 750 W electric motor that is located 100 feet from the panel board. The voltage at the panelboard is 120 volts. The permissible line drop is 1.2 volts. (for your final answer: no decimal places and unit to have one common answer)arrow_forward
- In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forwardThe plans indicate that you should install a 300 amp branch circuit in schedule 40 PVC with a 4AWG equipment grounding conductor. However, you did not have any 4AWG so you pulled 10AWG instead. With a load connected, the normal circuit current will be ___arrow_forward___________ is an Area on a device characteristic where the ratio between applied voltage and resulting current is constant.arrow_forward
- Most appliances of the type commonly used in bathrooms such as hair dryers, electric shavers and curling irons have two wire cords. These appliances are ____ insulated or ________ ___________arrow_forwardf.1. Since the footing or foundation is generally part of the grounding electrode system, the _______electrode is one of the first electrodes installed.A. metal water pipeB. plateC. concrete-encasedD. ground ringf.2. When you're connecting the grounding electrode conductor to a metal water pipe as it enters a building,the connection must be made within _______ feet of the pipe's entrance to the building.A. 10B. 5C. 15D. 7f.3. Which National Electrical Code table is used for sizing grounding electrode conductors?A. Table 250.102(C)(1)B. Table 250.66C. Table 250.122D. Table 250.118(6)(a)arrow_forward1)The NEC Style Manual indicates that if a term in the NEC appears in more than two articles, it qualifies for a definition in which of the following. a) The articles where the term appears b) Article 90 c) Article 100 d) Table of Contents 2)Definitions of terms related to grounding and bonding and used only in Article 250 are located in ________.a) Article 100 b) Article 200 c) Chapter 9 d) Section 250.2 3)As a general rule, when installing ground rod electrodes, two must be installed always unless a single ground rod provides not more than 25 ohms’ resistance to ground. a) True b) Falsearrow_forward