(a)
Interpretation:
The definition of the voltammograms is to be stated.
Concept introduction:
Cyclic voltammetry is a form of potentiodynamic
(b)
Interpretation:
The definition of hydrodynamic voltammetry is to be stated.
Concept introduction:
The hydrodynamic voltammetry technique is different from other voltammetry techniques which are unstirred experiments. The solution in the hydrodynamic voltammetry is kept stirring vigorously. The stirring can be provided by means of rotation of the electrode at a constant speed.
(c)
Interpretation:
The definition of Nernst diffusion layer is to be stated.
Concept introduction:
The diffusion layer is a region adjacent to the electrode, where the concentrations are different from that in the solution.
At slower rates of scan, the diffusion layer is large whereas at faster rates of the scan, the diffusion layer is comparatively small.
(d)
Interpretation:
The definition of mercury film electrode is to be stated.
Concept introduction:
Voltammetry involves plotting the current against the applied potential. This type of measurement is usually used to study the electrochemical properties of the analytes in the solutions or the molecules that have been adsorbed on the electrode. There are a variety of voltammetry methods available. These include linear sweep voltammetry, staircase voltammetry, alternating current voltammetry etc.
(e)
Interpretation:
The definition of half wave potential is to be stated.
Concept introduction:
For any given electrolyte, half wave potential is unique for each of the elements and for it’s different valence states and forms. Observation of the peak current at any specific half wave potential helps in identification of the chemical species that produces the current.
(f)
Interpretation:
The definition of voltammetric sensor is to be stated.
Concept introduction:
Voltammetric sensor is a device that is used for the purpose of carrying out voltammetry measurements.
It acts as an electrode in this process and helps determine the electrochemical properties of the analyte in the solution.
Want to see the full answer?
Check out a sample textbook solutionChapter 25 Solutions
PRINCIPLES OF INSTRUMENTAL ANALYSIS
- Choose the option that is decreasing from biggest to smallest. Group of answer choices: 100 m, 10000 mm, 100 cm, 100000 um, 10000000 nm 10000000 nm, 100000 um, 100 cm, 10000 mm, 100 m 10000000 nm, 100000 um, 10000 mm, 100 cm, 100 m 100 m, 100 cm, 10000 mm, 100000 um, 10000000 nmarrow_forwardQ1. (a) Draw equations for homolytic and heterolytic cleavages of the N-H bond in NH3. Use curved arrows to show the electron movement. (b) Draw equations for homolytic and heterolytic cleavages of the N-H bond in NH4*. Use curved arrows to show the electron movement.arrow_forwardWhich is NOT the typical size of a bacteria? 1000 nm 0.001 mm 0.01 mm 1 umarrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Chemistry: Principles and PracticeChemistryISBN:9780534420123Author:Daniel L. Reger, Scott R. Goode, David W. Ball, Edward MercerPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning