Name the article of the NEC that describes the central heating equipment and mention the name of the branch circuit that requires to be supplied to the central heating equipment system.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Follow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).
The Code places a maximum open-circuit voltage on lighting equipment in oron homes. This maximum voltage is 600 750 1000. (Circle the correctanswer.) Where in the NEC is this voltage maximum referenced?
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________.
a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basin
Chapter 24 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 24 - Prob. 1RCh. 24 - Prob. 2RCh. 24 - Prob. 3RCh. 24 - In a home, the low-voltage wiring between the...Ch. 24 - Prob. 5RCh. 24 - The nameplate on a transformer will indicate...Ch. 24 - If Class 2 conductors are insulated for 150 volts,...Ch. 24 - If you use 600-volt rated conductors for Class 2...Ch. 24 - The NEC is very strict about securing anything to...Ch. 24 - Does the Code permit attaching the low-voltage...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- An electrician installs five 3 AWG THWN copper current-carrying conductors in a raceway located in a garage. The garage area is subject to an ambient temperature of 100°F. All terminations are rated at 75°C.Ampacity: __________ Maximum Fuse or Circuit Breaker Size: __________.(NO CHAT GPT, ONLY NEAT HAND WRITTEN SOLUTION PLEASE.)arrow_forwardIf a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forwardPlease provide Handwritten answer Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.arrow_forward
- oleg is using a multimeter to test the circuit branch he's just installed. after turning off the current to the circuit at the service panel, he'll first attach one probe to the ----- in the end of the run. a. black wire b. box c. white wire d. ground wire Please answer with explanation In typing formatarrow_forward13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5arrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward
- 2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forwardMultiple choicesarrow_forward
- Food-waste disposers include a small manual reset button to restart the motor if it overheats and goes off-line due to prolonged use, something falls into the unit and jams it, or another cause. This manual reset provides the ____ protection required by Code for this type of appliance. A. short-circuitB. ground-faultC. overloadD. all of thesearrow_forward45. A switch or circuit breaker can be used as both the controller and disconnecting means if it a. opens all ungrounded conductors as required by NEC 430.103 b. is protected by an overcurrent device in each ungrounded conductor c. is manually operable, or both power and manually operable d. All of these answersarrow_forward1)The NEC Style Manual indicates that if a term in the NEC appears in more than two articles, it qualifies for a definition in which of the following. a) The articles where the term appears b) Article 90 c) Article 100 d) Table of Contents 2)Definitions of terms related to grounding and bonding and used only in Article 250 are located in ________.a) Article 100 b) Article 200 c) Chapter 9 d) Section 250.2 3)As a general rule, when installing ground rod electrodes, two must be installed always unless a single ground rod provides not more than 25 ohms’ resistance to ground. a) True b) Falsearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT