Architectural Drafting and Design (MindTap Course List)
Architectural Drafting and Design (MindTap Course List)
7th Edition
ISBN: 9781285165738
Author: Alan Jefferis, David A. Madsen, David P. Madsen
Publisher: Cengage Learning
bartleby

Concept explainers

Question
Book Icon
Chapter 24, Problem 24.1Q
To determine

The circumstances under which drafter is required to draw three elevations.

Expert Solution & Answer
Check Mark

Answer to Problem 24.1Q

A heat pump supplies up to three times as much heat per year for the same amount of electrical consumption as a standard electric forced-air system.

Explanation of Solution

An elevation is defined as an orthographic drawing thatdisplays 1 side of a building parallel to the picture plane. The elevation isdisplayed in true orthographic projection. The drawing of elevationdisplays the exterior finishes and shapes and the vertical relationships of the building levels.

The circumstances under which drafter is required to draw three elevations are as follows:

  • Number of elevations required
  • Where the elevations are to be set
  • The type of elevations to be drawn
  • The Elevations Scale
  • How the elevations are determined

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
By using the yield line theory, determine the ultimate resisting moment per linear meter (m) for an isotropic reinforced concrete two-way simply supported triangle slab shown in figure under a uniform load (q). Solve by using equilibrium method m m
The tension in cable BA is 10 kN. The questions will lead you toward determining the moment of the force acting from B to A about the x-axis. Hints: Pay attention to the orientation of the XYZ coordinate axes. 1000 mm A (400, 300, 0) mm 600 mm x
The beam shown in the figure below is typical for a floor system in an existing building.It needs to carry a uniform live load of 260 lb/ft and a uniform dead weight of 400 lb/ft,including its own weight. The owner wants to add a partition weighing 7 kip (live load) asshown. Assuming the added partition as live load, is the beam section adequate to safelycarry the extra live load?PartitionStirrups15 ft 3 in.14 in.a. Determine the d e s i g n m o m e n t c a p a c i t y .b. D e t e r m i n e t h e f a c t o r e d a p p l i e d b e n d i n g m o m e n t .c. Is the beam safe and adequate for bending? Please explain your response.
Knowledge Booster
Background pattern image
Civil Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Architectural Drafting and Design (MindTap Course...
Civil Engineering
ISBN:9781285165738
Author:Alan Jefferis, David A. Madsen, David P. Madsen
Publisher:Cengage Learning
Text book image
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781285852225
Author:Gregory W Fletcher
Publisher:Cengage Learning