Electrical Wiring: Residental - With Plans (Paperback) Package
18th Edition
ISBN: 9781305416376
Author: MULLIN
Publisher: Cengage
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
thumb_up100%
Chapter 23.2, Problem 7R
To determine
Whether is it permissible to connect 50-ampere circuit breaker or not when a central air-conditioning unit is installed and labelled as “Maximum Size Fuse 50 Amperes”.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.
Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________.
a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basin
Follow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).
Chapter 23 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 23.1 - a. What is the allowance in watts made for...Ch. 23.1 - What are some of the advantages of electric...Ch. 23.1 - List the different types of electric heating...Ch. 23.1 - There are two basic voltage classifications for...Ch. 23.1 - What device is required when the total connected...Ch. 23.1 - Prob. 6RCh. 23.1 - Prob. 7RCh. 23.1 - A certain type of control connects electric...Ch. 23.1 - What advantages does a 240-volt heating unit have...Ch. 23.1 - The white wire of a cable may be used to connect...
Ch. 23.1 - Receptacle outlets furnished as part of a...Ch. 23.1 - The branch circuit supplying a fixed electric...Ch. 23.1 - Prob. 13RCh. 23.1 - For ballpark calculations, the wattage output of a...Ch. 23.1 - A central electric furnace heating system is...Ch. 23.1 - What section of the Code provides the correct...Ch. 23.1 - Electric heating cable embedded in plaster, or...Ch. 23.2 - Prob. 1RCh. 23.2 - Prob. 2RCh. 23.2 - Prob. 3RCh. 23.2 - a. Must an air conditioner installed in a window...Ch. 23.2 - Prob. 5RCh. 23.2 - What is the Code requirement for receptacles...Ch. 23.2 - Prob. 7RCh. 23.2 - When the nameplate on an air-conditioning unit...Ch. 23.2 - Prob. 9RCh. 23.2 - Match the following terms with the statement that...Ch. 23.2 - The disconnect for an air conditioner or heat pump...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Connect the initial circuit as shown in Figure 47-1.2. Set VA at 20 volts. Insert a jumper wire between points A and B and observe the meter action.OBSERVATION Current flowed for approximately ___________ seconds as evidenced by the voltagemeasured across R. The rate of charge was (linear, nonlinear) __________________.nCONCLUSION The current that flowed was the charging current that charged the capacitor to avoltage equal to (VR, VA) ____________________. Was charging current maximum atthe beginning of the charge time or near the end? _________. At the beginning of thecharge time, the voltage across R was equal to (VC , VA) _______________________(the first instant). At the end of the charge time, the voltage across the resistor is________ volts; the voltage across the capacitor is equal to VA.arrow_forwardiF AN AMMETER WAS CONNECTED BETWEEN SWITCH1 AND POTENTIOMETER R1, HOW MUCH CURRENT WOULD IT INDICATE AT E(min) and E(max) IE(min)=__________________________mAdc IE(max)=__________________________mAdcarrow_forwardIf a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forward
- An 800 amp fuse rated at 600 volts _____ on a 250 volt system. A. shall not be usedB. must be usedC. shall be permitted to be usedD. none of thesearrow_forward45. A switch or circuit breaker can be used as both the controller and disconnecting means if it a. opens all ungrounded conductors as required by NEC 430.103 b. is protected by an overcurrent device in each ungrounded conductor c. is manually operable, or both power and manually operable d. All of these answersarrow_forwardTwo of the circuits will be a 3-wire, multi-wire branch circuit (Edison 3-wire). The location of the devices is to be determined by the student. The student shall be responsible for selecting the correct circuits, do not ask the instructor which circuit number should be used. Circuit A. One lampholder and one duplex receptacle controlled by a Single Pole Switch. Circuit B. Single Pole Switch controlling the top half of a duplex receptacle that when energized, is indicated by a Pilot-light at the Single Pole Switch location; plus an Isolated Ground Duplex Receptacle that is always hot. Circuit C. The bottom half of the switched receptacle on Circuit ‘B’ is to be always hot; plus another Duplex Receptacle that is controlled from two locations using a Coast 3-Way wiring-system.arrow_forward
- Determine the proper size of copper wire conductor necessary to apply a 750 W electric motor that is located 100 feet from the panel board. The voltage at the panelboard is 120 volts. The permissible line drop is 1.2 volts. (for your final answer: no decimal places and unit to have one common answer)arrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forward2. When working on a high - voltage system , it is best to keep anyone who is not part of the ser vice away from you and the car by creating a buffer zone around the car . Technician A makes sure the outside edges of the zone are at least one foot away from the car . Technician B places B orange cones to define the outer boundaries of the zone. Who is correct ?arrow_forward
- 5. When seeking to measure the voltage of a wall outlet (120 Volts AC) an electie: needs to do the following to prepare the Simpson 260 meter for measurement an the words to make the following statements correct). a. Set the function switch to b. The black lead should be inserted in the jack. c. The red lead should be inserted in the jack. d. The range switch should be set to the position. Note the safety warning at the heading of Section 4.10. The Simpson folks are serious about this and so should we all be. 150 assign_ELTE108_Handout_Lab_02_2020-02-05 Page 4 of 12arrow_forwardA circuit breaker is _______________________ a. used to detect a fault b. has a fuse elment c. has 3 contacts d. used at low voltage onlyarrow_forwardWhich of the following installations for a kitchen waste disposal that operates on a 15-ampere, 120-volt branch circuit requires AFCI protection? (Circle the correct answer.) a. The disposal operates by a switch that is installed above the kitchen counter. b. The disposal operates by a switch that is installed under the counter next to the disposal. c. Both (a) and (b) d. Neither (a) nor (b).arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT