A current transformer has a secondary with 250 turns and a current reading of 400 mA. What is the magnitude of the current being measured? Does the result clearly show one of the benefits of using current transformers?
Expert Solution & Answer

Want to see the full answer?
Check out a sample textbook solution
Students have asked these similar questions
-7 Name some of the factors that contribute to
the deterioration of organic insulators.
-8 A motor is built with class H insulation.
What maximum hot-spot temperature can it
withstand?
Calculate the full-load current of a 250 hp,
230 V dc motor having an efficiency of
92 percent.
Assignment #2
A 110-V, three-phase, Y-connected, 8 pole, 48-slot, 6000-rpm,
double-layer wound, synchronous generator has 12 turns per coil.
If one side of the coil is in slot 1, the other side is in slot 6. There
are 4 parallel paths. When the generator delivers the rated load at
a line voltage of 110 V, the voltage regulation is 5%. What is the
flux per pole?
Draw two consecutive phasegroups of one of the phase windings
and connect them (a) in series and (b) in parallel showing the
Start (S) and Finish (F) of both connections. (A separate drawing
for each connection)
Chapter 23 Solutions
Introductory Circuit Analysis (13th Edition)
Ch. 23 - For the air-core transformer in Fig. 23.57: Find...Ch. 23 - Repeat Problem 1 if k is changed to 1. Repeat...Ch. 23 - RepeatProblem1fork=0.3,NP=300turns,andNS=25turns.Ch. 23 - For the iron-core transformer (k = 1) in Fig....Ch. 23 - RepeatProblem4forNP=240andNS=30.Ch. 23 - Find the applied voltage of an iron-core...Ch. 23 - If the maximum flux passing through the core of...Ch. 23 - For the iron-core transformer in Fig. 23.59: Find...Ch. 23 - Find the input impedance for the iron-core...Ch. 23 - Find the voltage Vg, and the current Ip if the...
Ch. 23 - If VL=240V,ZL=20resistor,Ip=0.05AandNs=50 find the...Ch. 23 - If Np400,Ns=1200andVg=100V,findthemagnitudeofIp...Ch. 23 - For the circuit in Fig. 23.60, find the...Ch. 23 - For the transformer in Fig. 23.61, determine the...Ch. 23 - For the transformer in Fig. 23.61, if the...Ch. 23 - Prob. 16PCh. 23 - Discuss in your own words the frequency...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Write the mesh equations for the network in Fig....Ch. 23 - Determine the input impedance to the air-core...Ch. 23 - An ideal transformer is rated...Ch. 23 - Determine the primary and secondary voltages and...Ch. 23 - For the center-tapped transformer in Fig. 23.42,...Ch. 23 - For the multiple-load transformer in Fig. 23.43,...Ch. 23 - Prob. 27PCh. 23 - Write the mesh equations for the network of Fig....Ch. 23 - Write the mesh equations for the network of Fig....Ch. 23 - A current transformer has a secondary with 250...Ch. 23 - Generate the schematic for the network in Fig....Ch. 23 - Prob. 32PCh. 23 - Using a transformer from the library find the load...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 3-4 Transmissiva Live of 120km has R= 0.2 ~2/15 X= 0.8 -2/km Y = 15H/6 5/km The line is supplies a load of 45 kV, SOMW, 0.8 lead p.f find sending voltage, Sending Current p.f. Sanding Voltage Regulation ⑨Voltage 5 Ⓒ charching coming! изу usy π cct लेarrow_forwardA (medium) single phase transmission line 100 km long has the following constants : Resistance/km = 0.25 Q; Susceptance/km = 14 × 10° siemen ; Reactance/km = 0.8 Receiving end line voltage = 66,000 V Assuming that the total capacitance of the line is localised at the receiving end alone, determine (i) the sending end current (ii) the sending end voltage (iii) regulation and (iv) supply power factor. The line is delivering 15,000 kW at 0.8 power factor Lead Draw the phasor diagram to illustrate your calculations.arrow_forward1. An electromagnetic device is shown below. The coil in the left side is connected to a steady AC power source. The left coil generates a changing magnetic flux, which is = 1.5cos(120πt +л/6) T. Calculate the voltage vs generated across the right coil given the number of turns of the right coil is 5 (You only need to calculate the magnitude). Vparrow_forward
- For the closed loop system shown in figure, determine the following:arrow_forwardWhat is the open loop transfer function and feedback for thia system? Determine the type of the open loop system. Find the poles s1 and s2 of the open loop system. If the input is a step function R(s)=1/s, find the step response c(t) of the open loop.arrow_forwardnot use ai please don'tarrow_forward
- 2. A DC generator is shown below. This DC generator is driven by a prime mover and rotating in counterclockwise direction. The armature is connected with a load resistor. (i) Using cross (x) or dot (*) to indicate the current direction of each conductor in the armature. (ii) If we want to reverse the polarity of the generated armature voltage, what can we do to? rotation S load Narrow_forward6. The figures below show the equivalent circuit of a separately excited DC generator and the approximate relationship between the flux of main field and exciting current. The field current I can be regulated by the variable resistor Ry, and the battery voltage supplying power to the exciter is 12V. The armature resistance Ro is 20, and the load is 182. For the DC generator, we aim to keep the voltage across the load (RL) constant in different speed range conditions. In the beginning, the flux is 0.12 Wb, the DC generator speed is 1000 rpm, and the generated voltage E。 is 100 V. Calculate: (1) The current flowing through the load. (2) When the speed of generator changes to 1500 rpm, how should we adjust the exciting current Ix to ensure Ę is still 100 V. (Hint: E₁ = Zno/60) (3) When the speed of generator changes to 500 rpm, how should we adjust the exciting current Ix to ensure Eo is still 100 V. (Hint: Eo = Zno/60) Rf ww (Wb) 0.17 0.15 12 V 1x F ele 1 1 2 ell Eo Ro ww 9 w RL Ix (A)arrow_forward7. For a shunt excited motor, the maximum allowable current is twice of the full-load current. The full-load current is 10 A. The equivalent circuit of this motor is also shown below. The rheostat can change the resistance by moving the slider (contact). The counter electromotive force (CEMF) for this motor is 100 V at 1000 rpm. The power supply E, is 200 V. In this case: (1) Calculate the minimum resistor value R at 0 rpm ensuing the motor is running within the safe range, and calculate the power consumed by the rheostat R. (2) Calculate the minimum effective resistor value R at 100 rpm ensuing the motor is running within the safe range, and calculate the power consumed by the rheostat R and the delivered mechanical power. (3) Calculate the minimum resistor value R at 500 rpm ensuing the motor is running within the safe range, and calculate the power consumed by the rheostat R the delivered mechanical power. shunt field R armature rheostat Es + Eoarrow_forward
- 4. For a general DC generator, we aim to achieve constant output voltage at different rotating speeds. (1) List two factors influencing the output voltage for a given DC generator. (2) How does the change of the load (assuming the load is the current flowing though the resistor) will impact on the generated voltage for (a) separately excited DC generator, (b) Shunt DC generator, and (c) cumulative compound DC generator?arrow_forward3. A DC motor is shown below. The armature is supplied by an external battery, and the current flowing direction of each conduction is depicted in the figure. (i) Draw the Lorentz force direction applied on each conductor in the armature. (ii) In which direction will the motor spin? What can we do to reverse the spinning direction? S Narrow_forward5. conditions. For a general DC motor, we aim to control the speed of the motor at different loading (1) List two factors influencing the motor speed for a given DC motor. (2) List three ways to stop a motor and comment on each method?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning

Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
TRANSFORMERS - What They Are, How They Work, How Electricians Size Them; Author: Electrician U;https://www.youtube.com/watch?v=tXPy4OE7ApE;License: Standard Youtube License