Understanding Motor Controls
4th Edition
ISBN: 9781337798686
Author: Stephen L. Herman
Publisher: Delmar Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 21, Problem 3RQ
Refer to Figure 21–1 to answer the following questions.
Referring to switch (RS SW 123), in what position must the switch be set to make connection between terminals 3 and 4?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Name
Section 5-2: Line Diagrams-Signals,
Decisions, and Actions
In the following application, a temperature switch controls a heating contactor and a flow switch is used to
ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required
information.
1. List all the signal devices in the circuit.
2. List all the action devices in the circuit.
3. List the decision part of the circuit that automatically sounds the alarm if there is a problem.
4. When the heating element is on during normal operation, is the flow switch open or closed?
CIRCULATING
2
L1
FAN
TEMPERATURE
SWITCH
TR
HEATING
ELEMENTS
FLOW
SWITCH
-HOT AIR
PADDLE
AIR FILTER
NORMALLY CLOSED
FLOW SWITCH
65
ALARM
(SOUNDS IF NO FLOW FOR
15 SECONDS OR MORE)
Date
HEATING
CONTACTOR
TR
ON-DELAY
TIMER
SUPPLY AIR
COLD AIR
(3) TIME SET= 15 SEC
© 2014 American Technical Publishers, Inc.
All rights reserved
Q1
Q1
---- -
Reduce the combinational logic circuit in figure 1 to minimum form.
Figure 1
B
C
D
Chapter 21 Solutions
Understanding Motor Controls
Ch. 21 - Refer to Figure 21–1 to answer the following...Ch. 21 - Refer to Figure 211 to answer the following...Ch. 21 - Refer to Figure 211 to answer the following...Ch. 21 - Prob. 4RQCh. 21 - Prob. 5RQCh. 21 - Prob. 6RQCh. 21 - Prob. 7RQCh. 21 - Refer to Figure 21–1 to answer the following...Ch. 21 - Refer to Figure 21–1 to answer the following...Ch. 21 - Prob. 10RQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to Figure 21–1 to answer the following questions. In what position must switch SW 123 be set to make connection between terminals 3 and 4?arrow_forwardRefer to Figure 21–1 to answer the following questions. When switch HOA SW 122 is in the off position, which contacts have connection between them?arrow_forwardRefer to the circuit shown in Figure 5-29. In this circuit, the HR contactor is equipped with five contacts. Three are load contacts and two are auxiliary contacts. From looking at the schematic diagram, how is it possible to identify which contacts are the load contacts and which are the auxiliary contacts? Figure 5-29 The contactor contains both load and auxiliary contacts.arrow_forward
- Following the procedure discussed in Chapter 7, place wire numbers on the schematic in Figure 8–7. Place corresponding wire numbers on the components shown in Figure 8–8.arrow_forwardRefer to the circuit shown in Figure 7-10. If wire number 11 were disconnected at the normally open auxiliary M contact, how would the circuit operate? Figure 7-10 Numbers are placed beside all components.arrow_forwardSelect the proper choice(s) for each of the following statements: 1) To control single-acting cylinder we just need: double-acting cylinder we should use A2/2-way, 5/2-way, (C) 3/3-way, 3/4-way, 2) In DCV. (B) 3/2-way, 4/2-way, (D) 4/3-way, 3/2-way. mid poistion of DCV, we can move cylinder piston rod freely without resistance by hand. (A) working ports are exhausted, (C) working ports are pressurized, 3) In pneumatics we use A Compressor (B) Pump, DCV, while to control the 4) Quick exhaust valve is used to (A) increase the cylinder return speed. (C) meter-out the cylinder speed (B) all ports are closed. no one of these options. to obtain high pressure air. (C) Turbine, (D) pressure relief valve. (B) meter-in the cylinder speed, (D) increase the cylinder extending speed. 6) Meter-in of cylinder movement is used to control the Afluid that enters the hydraulic cylinder, (B) fluid that exits the hydraulic cylinder, (C) fluid that enters the DCV (D) fluid that exits the DCV. 5) One of the…arrow_forward
- Refer to the circuit shown in Figure 3311. You are to construct this circuit on the job. Would it be possible to use an 11 pin control relay for 4CR?arrow_forwardHelp me solve this question ASAP !!arrow_forwardRefer to the circuit shown in Figure 42–21. Assume that a fused jumper is connected across terminals 1 and 3 of TR2 timer. What would happen if the jumper were left in place and the FIRST SPEED push button pressed? The motor would start in its lowest speed and progress to second speed, but never increase to third speed. The motor would start operating immediately in third speed. The motor would not start. The motor would start in second speed and then increase to third speed.arrow_forward
- Refer to the schematic diagram in Figure 318. Assume that the motor is not running. When the third speed push button is pressed, the motor starts in its lowest speed. After a delay of 3 seconds, the motor accelerates to second speed and 3 seconds later to third speed. After a period of about 1 minute, the fourth speed push button is pressed, but the motor does not accelerate to fourth speed. Which of the following could cause this problem? a. Control relay CR2 coil is open. b. S2 contactor coil is open. c. CR3 coil is shorted. d. S3 contactor coil is open.arrow_forwardRefer to the circuit shown in Figure 25–5. Assume that timer TR1 is set for a delay of 10 seconds and timer TR2 is set for a delay of 5 seconds. When the START button is pressed, the motor starts. After 10 seconds the S1 contacts open and the motor continues to accelerate, but never reaches full speed. After a delay of about 30 seconds, the motor trips out on overload. Which of the following could cause this problem? TR1 coil is open. S2 coil is open. S1 coil is open. R coil is open.arrow_forwardPlease helparrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
- Precision Machining Technology (MindTap Course Li...Mechanical EngineeringISBN:9781285444543Author:Peter J. Hoffman, Eric S. Hopewell, Brian JanesPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Precision Machining Technology (MindTap Course Li...
Mechanical Engineering
ISBN:9781285444543
Author:Peter J. Hoffman, Eric S. Hopewell, Brian Janes
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY