Chapter 2.1, Problem 31R
a.
To determine
Find the maximum possible number of 12 AWG conductors permitted in the
b.
To determine
Find the maximum possible number of 12 AWG conductors permitted in the
c.
To determine
Find the maximum possible number of 12 AWG conductors permitted in the
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
1.1 PV modules can be wired together in an array using ______ connections to increase voltage.
a. Terminating
b. Series
c. Parallel
d. AC
1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit.
a. Capsules
b. Compartments
c. Chips
d. Cells
1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy.
a. Direct coupled
b. Self regulating
c. Charge controlled
d. Indirectly connected
1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage.
a. Coal
b. Natural Gas
c. Diesel
d. Solar
Using Table 2- 1, calculate the total minimum volume requirements for the box. The box contains (2) switches, (2) 14/3 romex w/grd, (2) 14/2 romex w/grd, no clamps or accessories. All conductors are spliced or pig tailed.
Select one:
a. 20 cu. in.
b. 24 cu. in.
c. 28 cu. in.
d. 30 cu. in.
4.A. The insulation color of a grounded wire should beA. white.B. red.C. black.
4.B. A switch is always installed in a circuit so that it's connected to theA. grounding wire.B. ungrounded conductor.C. neutral wire.
Chapter 2 Solutions
Electrical Wiring Residential
Ch. 2.1 - What is the purpose of specifications?Ch. 2.1 - Refer to the specifications in the back of this...Ch. 2.1 - What is done to prevent a plan from becoming...Ch. 2.1 - Name three requirements contained in the...Ch. 2.1 - Prob. 5RCh. 2.1 - What phrase is used when a substitution is...Ch. 2.1 - What is the purpose of an electrical symbol?...Ch. 2.1 - Prob. 8RCh. 2.1 - Prob. 9RCh. 2.1 - What three parties must be satisfied with the...
Ch. 2.1 - What does a plan show about electrical outlets?...Ch. 2.1 - Prob. 13RCh. 2.1 - Prob. 14RCh. 2.1 - Prob. 15RCh. 2.1 - Prob. 16RCh. 2.1 - Prob. 17RCh. 2.1 - Prob. 18RCh. 2.1 - Prob. 19RCh. 2.1 - What methods may be used to mount luminaries to an...Ch. 2.1 - What advantage does a 4 in. octagon box have over...Ch. 2.1 - What is the size of the opening of a switch...Ch. 2.1 - Prob. 23RCh. 2.1 - Prob. 24RCh. 2.1 - Prob. 25RCh. 2.1 - Prob. 26RCh. 2.1 - Prob. 27RCh. 2.1 - Prob. 28RCh. 2.1 - Prob. 29RCh. 2.1 - Prob. 30RCh. 2.1 - Prob. 31RCh. 2.1 - Prob. 32RCh. 2.1 - Prob. 33RCh. 2.1 - Prob. 35RCh. 2.1 - Prob. 37RCh. 2.1 - Prob. 38RCh. 2.1 - Prob. 39RCh. 2.1 - Prob. 40RCh. 2.1 - Prob. 42RCh. 2.1 - Does the NEC allow metal raceways to be used with...Ch. 2.2 - Prob. 1RCh. 2.2 - What is the size of the footing for the steel...Ch. 2.2 - Prob. 3RCh. 2.2 - Prob. 4RCh. 2.2 - Prob. 5RCh. 2.2 - Prob. 6RCh. 2.2 - How far is the front garage wall from the curb?...Ch. 2.2 - How far is the side garage wall from the property...Ch. 2.2 - Prob. 9RCh. 2.2 - What is the purpose of the I-beams that rest on...Ch. 2.2 - Where is access to the attic provided?...Ch. 2.2 - Prob. 13RCh. 2.2 - Prob. 14RCh. 2.2 - Prob. 15RCh. 2.2 - Prob. 16RCh. 2.2 - What is the stud size for the partitions between...Ch. 2.2 - Who is to furnish the range hood?...Ch. 2.2 - Who is to install the range hood?...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forward1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forward
- 20. If a steel ground rod is used as a grounding electrode, the rod must have a minimum diameter of_______ inch.A. 5/8B. 1/2C. 1/4D. 3/8arrow_forwardCOLUMN A COLUMN B A copper wiring containing 8 color-coded 1. conductors or 4 twisted pairs that offers greater bandwidth for local area networks. A. LEGEND 2. distribution device. A wiring pattern that connects to a central B. HOMERUN 3. Another term for an 8-pin modular jack. C. OVERCURRENT 4. A coaxial cable quad shielded with all copper center conductor used for cable TV. D. INSULATOR It is the maximum current that a conductor can 5. carry without exceeding its temperature rating. E. SHORT CIRCUIT 6. A wiring job where many cables enter a device or a junction box that is considered an unsafe practice in electrical wiring, F. CIRCUIT BREAKER 7. An electrical safety device designed to protect an electrical circuit from damage. G. ARC FLASH 8. unintended path with very low resistance. Occurs when an electrical current flows in an H. AMPACITY 9. amperage capacity of the circuit. Occurs when the current exceeds the rated I. UTP 10. A method of extending an electrical wire to the ground…arrow_forwardof p o How many conductors enter the ceiling fan/light wall box? Switch ond out let boxes s tirst 10. What type and size of box may be used for the ceiling fan/light wall box?. 11. What type of covers are used with 4 in. square outlet boxes? 12. a. Does the circuit for the Master Bedroom have a grounded circuit conductor? b. Does it have an equipment grounding conductor? c. Explain the difference between a "grounded" conductor and an "equipment grounding" conductor. 13. Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to ft complete the circuit supplying the Master Bedroom? Two-wire cable: ft (- m). m). Three-wire cable: 14. If the cable is laid in notches in the corner studs, what protection for the cable must be provided? 15. How high are the receptacles mounted above the finished floor in this bedroom? 16. Approximately how far from the bedroom door is the first receptacle mounted? (See the plans.) 17. What is the distance from the finished floor to…arrow_forward
- QUESTION 5 A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle? a It must be secured by at least two screws. b The single 6/32 screw holding it in the cover must be tight. c It must be secured directly to the 4 inch square box. d It is not permitted to be installed in raised covers.arrow_forward5. How many system bonding jumpers normally are there for a separately derived system that's grounded? A. ThreeB. TwoC. One D. Zero 6. How many grounded neutral conductors are in a 208Y/120 volt, 3-phase, 4-wire system? A. ThreeB. TwoC. One D. Four 7. Which of the following are sometimes installed as an emergency system, legally required standby system, or optional standby power system for a building or structure? A. GeneratorsB. Surge protection devices C. Surge arrestersD. Transformers 8. If the system bonding jumper in a DC system is a screw, what color must the screw be? A. WhiteB. RedC. Orange D. Green 9. If overcurrent protection is provided in the transformer of a separately derived system, which of the following statements is correct? A. An equipment grounding conductor must be run with the conductors between the transformer and the building's disconnect. B. There's no need for service equipment or a panelboard in the separate building.C. A ground electrode must…arrow_forward14: In a natural circulation solar water heater, collector has a glass cover on the top and an ________________ material at the bottom. a. Insulating b. Sheets c. Steel d. Tubes 15: text ____________ wind mill consists of narrow rims and wire spokes. a. Single bladed b. Vertical Axis c. Double bladed d. Multibladedarrow_forward
- Which of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forward4.a. The ___ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total 4.b. What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight 4.c. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.arrow_forward
arrow_back_ios