Question
Chapter 21, Problem 10RQ
To determine
The size of conductor for the branch circuit supply.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 3 kVA motor operates from a 240 V
supply at 50 Hz and has a power
factor of 0.6. Determine the active
power
Select one:
1800 W
Non of the Answers
1900 W
2000 W
A 3-phase, 50 Hz, 3000 V motor develops 600 H.P. (447·6 kW), the power factor being 0·75 lagging andthe efficiency 0·93. A bank of capacitors is connected in delta across the supply terminals and powerfactor raised to 0·95 lagging. Each of the capacitance units is built of five similar 600-V capacitors.Determine the capacitance of each capacitor.
The following data were obtained on a 50 kVA 2400/120 V transformer:
Open circuit test, instruments on low voltage side:
Waltmeter reading = 396 Watts
Ammeter reading = 9.65 amperes
Voltmeter reading = 120 Volts
Short circuit test, instruments on high voltage side:
Waltmeter reading = 810 Watts
Ammeter reading = 20.8 amperes
Voltmeter reading = 92 Volts
Find the efficiency when rated kVA is delivered to a load having a power
factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer :
Open circuit test, instruments on low voltage side:
Waltmeter reading = 396 Watts
Ammeter reading = 9.65 amperes
Voltmeter reading = 120 Volts
Short circuit test, instruments on high voltage side:
Waltmeter reading = 810 Watts
Ammeter reading = 20.8 amperes
Voltmeter reading = 92 Volts
Find the efficiency when rated kVA is delivered to a load having a power
factor of 0.8 lagging.
Chapter 21 Solutions
Electrical Transformers and Rotating Machines
Knowledge Booster
Similar questions
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forward
- How does the National Electrical Code specify that the high leg of a four-wire delta connection be marked?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forwardFind the value of the currents I1 and 12. 100 ohm 5V 5V 100 ohm 12 O a. 1=-0.3A, 12=-0.1A O b. 11=0.3A, 12=0.1A Oc. 11=0.05A, 12=0.1A O d. 11=0.1A, 12=0.2Aarrow_forward
- Question 4 A 228 V/ 111 V single-phase transformer has a core loss of 110 W and the no-load current is 0.7 A. The no load power factor is Not yet answered Marked out of O 0.99 1.00 O 1.42 P Flag question O 0.48 O 0.69 Question 5 A 2 kV / 229 V transformer has the secondary turns of 47. The number of Primary turns of a transformer is given by, Not yet answered 63.83 Marked out of 410.48 1.00 O 615.72 P Flag question O 5381.50 Question 6 For the given power transfer, a delta system is associated with larger line currents and a star system is associated with a larger line voltage. Not yet answered Select one: Marked out of O True 1.00 P Flag question O Falsearrow_forwardTwo shunt generators 1 and 2 are operating in parallel. The voltage of generator 1 falls from 240 V at no-load to 220 V at 200 A, while that of generator 2 falls from 245 V at no-load to 220 at 150 A. Determine the current which each generator supplies to n common load of 300 A and the bus-bar voltage at this load. The load characteristics of the generators may be taken as straight lines.arrow_forwardA balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, powerarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning