Question
Chapter 18, Problem 3RQ
To determine
The word in the blank space of the given statement.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionChapter 18 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
Knowledge Booster
Similar questions
- The most often used category-rated UTP cable for voice and data wiring from various outlets back to the service center or other distribution device in a residential application is______. (Objective 16-3)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forwardSmall-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forward
- Calculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work. (Objective 6-2)arrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forwardWhen wiring a split-wired receptacle, it is recommended that the part of the duplex receptacle controlled by a switch be the _______half and the part that is hot at all times is the ______ half. (Objective 18-3)arrow_forward
- Describe how a white Insulated conductor in a cable assembly is reidentified as an ungrounded hot conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardIf Type SER service entrance cable is used by an electrician to feed a subpanel from a main panel, the cable must be secured within _________of the panel enclosures and at Intervals not exceeding___________. Name the NEC section that states this requirement. (Objective 8-7)arrow_forward