The section code of the NEC that covers the necessary locations for Ground fault circuit interrupters in residential applications.
Explanation of Solution
NEC Section 210.8 deals with the locations needed for Ground fault circuit interrupters in residential applications. GFCI safety devices should be mounted in an immediately accessible location. GFCI security is necessary forthe residential electrical system in several regions outside and inside of the house.
GFCI receptacles are used to safeguard people from the dangers of electric shock. Ground fault circuit interrupter receptacles secure the places where they are mounted and may also secure standard duplex receptacles that are mounted farther along the circuit. A Ground fault circuit interrupter circuit breaker also protects ground-fault.
Conclusion:
NEC Section 210.8 with the locations needed for Ground Fault Circuit Interrupters in residential applications.
Want to see more full solutions like this?
Chapter 18 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
- List five guidelines for the care and safe use of electrical hand tools. (Objective 3-4)arrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forwardExplain how the NEC® and Underwriters Laboratories categorize general-use snap switches. (Objective 13-1)arrow_forward
- Small-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forwardDescribe the purpose of an LB conduit body used in a residential service entrance Installation that uses electrical conduit. (Objective 8-1)arrow_forwardIf Type SER service entrance cable is used by an electrician to feed a subpanel from a main panel, the cable must be secured within _________of the panel enclosures and at Intervals not exceeding___________. Name the NEC section that states this requirement. (Objective 8-7)arrow_forward
- Name and describe three cable types that can be used in residential electrical installations. (Objective 2-5)arrow_forwardQ-2 On sheet S.01 Please find the total amount of concrete in CY on all footing on Center line K Q-3 On sheet S.01 Please find the total amount of steel in Tones. on all footing on Center line K 04arrow_forwardlookN 20KN Salve for FAB 25E FCH 15KN FcD EDE 300 Sm A. 3m 3m 3m Sm 20CN 20KN 20KNarrow_forward
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage LearningResidential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781285852225Author:Gregory W FletcherPublisher:Cengage Learning