DELMAR'S STANDARD TEXT OF ELECTRICITY
6th Edition
ISBN: 9780357323380
Author: Herman
Publisher: CENGAGE C
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 18, Problem 3RQ
What is power factor?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. A three-phase, three-wire, 240 V, ABC system supplies a delta-connected load
in which ZAB = 25/90°, ZBC = 15230° and ZCA = 200°.
a) Find the line currents and the total real and reactive powers supplied by the
source. Draw the phasor diagram for the line voltages and phase and line
currents.
Vc
VA
AT
VB ICT
1
CA
ZAB
| BT
ZBC
b) A 240 V, 2 HP, 0.95 efficiency, single-phase motor is connected as shown
below. The motor is operating at 0.85 p.f. lagging. Repeat (a). Include the
motor current in the phasor diagram
VA
AT
ZAB
Ꮓ
ΑΒ
V
B
CT
1BT
M
ZBC
ZCA
2. A three-phase, four-wire, 208 V, ABC system supplies a Y-connected load in
which Zд = 100°N, Z = 15/30° and Zc = 104-30°. Find the line
currents, the neutral current and total real and reactive powers. Draw the phasor
diagram of the phase voltages and currents.
ZA
=
3. A three-phase, three-wire, 208 V, ABC system supplies a Y-connected load in
which ZA 100°, ZB = 15230° and Zc = 10-30°. Find the line
currents, the phase voltages across the load impedances, the total real and reactive
powers and the voltage Von
VA
ZA
Don't use ai to answer I will report you answer
Chapter 18 Solutions
DELMAR'S STANDARD TEXT OF ELECTRICITY
Ch. 18 - 1. What is the relationship of voltage and current...Ch. 18 - What is the relationship of voltage and current...Ch. 18 - 3. What is power factor?
Ch. 18 - 4. A circuit contains a 20- resistor and an...Ch. 18 - 5. An R-L series circuit has a power factor of...Ch. 18 - 6. An R-L series circuit has an apparent power of...Ch. 18 - 7. The resistor in an R-L series circuit has a...Ch. 18 - 8. An R-L series circuit has a reactive power of...Ch. 18 - 9. An R-L series circuit contains a resistor and...Ch. 18 - 10. What is the voltage drop across the resistor...
Ch. 18 - 11. A phase angle meter connected in an R-L series...Ch. 18 - 12. An R-L series circuit has a power factor of...Ch. 18 - An AC electric motor is connected to a 240-V,...Ch. 18 - You are a journeyman electrician working in an...Ch. 18 - Prob. 1PPCh. 18 - Assume that the voltage drop across the resistor,...Ch. 18 - Prob. 3PPCh. 18 - Prob. 4PPCh. 18 - In an R-L series circuit,...Ch. 18 - In an R-L series circuit,...Ch. 18 - In an R-L series circuit,...Ch. 18 - In an R-L series circuit, the apparent power is...Ch. 18 - 9. An R-L series circuit is connected to a 60-Hz,...Ch. 18 - In an R-L series circuit, Z=88,R=32.FindXL.Ch. 18 - In an R-L series circuit, apparent power = 450 VA,...Ch. 18 - In an R-L series circuit, =22, true power = 94...Ch. 18 - An R-L series circuit contains two resistors and...Ch. 18 - An R-L series circuit contains two resistors and...Ch. 18 - An R-L series circuit contains two resistors and...Ch. 18 - An R-L series circuit contains two resistors and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Discuss the importance of power-factor correction in a.c. systems. A 400 V, 50 Hz, three-phase distribution system supplies a 20 kVA, three-phase induction motor load at a power factor of 0.8 lagging, and a star-connected set of impedances, each having a resistance of 10 Ω and an inductive reactance of 8 Ω. Calculate the capacitance of delta-connected capacitors required to improve the overall power factor to 0.95 lagging. ANS: 75 µF/pharrow_forwardA 3-phase, wye-connected generator induces 2400 V in each of its windings. Calculate the line voltage.arrow_forwardwhy Low Pass filter (LPF) R₁C=S V₁ R т Tc Voarrow_forward
- Don't use ai to answer I will report you answerarrow_forwardA 60hp,3-phase motor absorbs 50 kW from a 600 V,3-phase line. If the line current is 60 A, calculate the following: a. The efficiency of the motor b. The apparent power absorbed by the motor c. The reactive power absorbed by the motor and the power factor of the motorarrow_forwardThree 15Ω resistors and three 8Ω reactors are connected as shown in Fig. 18. If the line voltage is 530 V, calculate the following: a. The active, reactive, and apparent power supplied to the 3 -phase load b. The voltage across each resistorarrow_forward
- Three resistors are connected in delta. If the line voltage is 13.2kV and the line current is 1202 A, calculate the following: A) the current in and the voltage acroos each resistor B) The power supplied to each resistor and the 3 phase load C) The ohmic value of each resistorarrow_forwardWith the aid of a phasor diagram show that the active power and power factor of a balanced three-phase load can be measured by two wattmeters. For a certain load, one wattmeter indicated 20 kW and the other 5 kW after the voltage circuit of this wattmeter had been reversed. Calculate the active power and the power factor of the load. ANS: 15 kW, 0.327arrow_forwardState the advantages to be gained by raising the power factor of industrial loads. A 400 V, 50 Hz, three-phase motor takes a line current of 15.0 A when operating at a lagging power factor of 0.65. When a capacitor bank is connected across the motor terminals, the line current is reduced to 11.5 A. Calculate the rating (in kVA) and the capa citance per phase of the capacitor bank for: (a) star connection; (b) delta connection. Find also the new overall power factor. ANS: 3.81 kvar, 70.5 µF, 23.5 µF, 0.848 laggingarrow_forward
- A single wattmeter is used to measure the total active power taken by a 400 V, three-phase induction motor. When the output power of the motor is 15 kW, the efficiency is 88 per cent and the power factor is 0.84 lagging. The current coil of the wattmeter is connected in the yellow line. With the aid of a phasor diagram, calculate the wattmeter indication when the voltage circuit is connected between the yellow line and (a) the red line, (b) the blue line. Show that the sum of the two wattmeter indications gives the total active power taken by the motor. Assume the phase sequence to be R–Y–B. ANS: 11.7 kW, 5.33 kWarrow_forwardPlease help mearrow_forwardDon't use ai to answer I will report you answer.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Series compensation of long transmission lines; Author: Georg Schett;https://www.youtube.com/watch?v=smOqSxFBvVU;License: Standard Youtube License