Refer to the circuit shown in Figure 16-11. Assume that the platform is located on the lower floor. When the UP push button is pressed, the platform rises. When the platform reaches the upper floor, however, the pump does not turn off but continues to run until the overload relay opens the overload contacts. Which of the following could cause this problem?
- a. The solenoid valve opened when limit switch LS1 opened.
- b. The UP push button is shorted.
- c. Limit switch LS1 did not open its contacts.
- d. Limit switch LS2 contacts did not reclose when the platform began to rise.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
(B) Choose the correct answer for the following statements:-
1- For a faster response time, a spool type of directional control valve use
a-Over lapping, b-Zero lapping, c- Under lapping, d- Non of them
FLUID POWER SYSTEMS
HYDRAULICS & ELECTRO-HYDRAULICS
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the circuit shown in Figure 15-6. If the circuit is in operation and an overload should occur on the lube oil pump and the overload contact open, would it affect the operation of the compressor?arrow_forwardRefer to the circuit shown in Figure 15-6. If an overload should occur on the compressor motor and the overload contact open, would it affect the operation of the lube oil pump?arrow_forward14-26. For the circuit of Figure 14-20, what happens to the cylinders in each case? a. Valve V1 is actuated and held. b. Valve V1 is released and valve V2 is actuated and held. Valves V3 and V4 are sequence valves.arrow_forward
- Need circuit and explain each question...if you do correctly i'll give thumps uparrow_forwardplease write clearly if handwritten so that I could read and understand the solutions and steps takenarrow_forwardGive the name of the following graphic symbols or Draw the graphic symbol according to the following name 4.(a) variable displacement motor (b) Pressure reducing valve (c) Directional control valve for 4-way, 3-position, O type neutral conditions (d) check valvearrow_forward
- 2. Draw and Explain the Circuit diagram for holding the cylinder of double acting cylinder in the fully extended position using 4/3 de valve?arrow_forwardThe symbol shown represents a: Normally Closed Pressure reducing valve. Normally Closed Pressure sequence valve. Normally Closed Count down valve. Normally Closed Count up valve. O Normally Closed Timer off delay valve. O Normally Closed Timer on delay valve.arrow_forwardWhat is the main reason for conducting a 3-point stroke test on the pneumatic control valves on the 3-phase separator? To ensure that the control valves are not stuck when the controllers require the control valves to open or close precisely. To ensure that the control valves can move rapidly based on the controllers' output. To check that the controllers are functioning properly. To check that the valve positioner scales are accurate.arrow_forward
- It is desired to operate the pneumatic cylinder below which has to pistons A and B to stamp the die D. The piston A s returned in its back stroke by a spring, and has quick return .It is advised to use solenoid and pilot valves DCV . ( best design is to use two DCV valves ) 1- Make a complete circuit layout to operate the device above, using the appropriate symbols.2-Describe in details how your system works ( typed ) 3- Names the components of your system. 4- Any pneumatic working design will be considered as correct.arrow_forward1. Two double acting pneumatic cylinders (A, B) in a process industry should extend together at the same time to open two different valves. On the return stroke both cylinder rods return at the same time. The starting is by a detent switch. Both the cylinders are of the same size with the same stroke length. In terms of notation, the cycle is required to go on till the detent start-up switch is pressed again. Draw the electro pneumatic circuit neatly. Briefly explain its operation. LB +J LB A В Y Y Y Y Varrow_forwardName one function of the low-pressure control.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY