Electrical Transformers and Rotating Machines
4th Edition
ISBN: 9781305494817
Author: Stephen L. Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 13, Problem 5RQ
To determine
Whether the transformer is derated or not and the magnitude of the derated amount.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
4. A circuit contains a 20-2 resistor and
an inductor with an inductance of
0.093 H. If the circuit has a frequency
of 60 Hz, what is the total impedance
of the circuit?
5. An R-L series circuit has a power
factor of 86%. By how many degrees
are the voltage and current out of
phase with each other?
6. An R-L series circuit has an apparent
power of 230 VA and a true power of
180 W. What is the reactive power?
7. The resistor in an R-L series circuit
has a voltage drop of 53 V, and the
inductor has a voltage drop of 28 V.
What is the applied voltage of the
circuit?
In three phase power measurement using one watt-meter method, if the load is balanced then the
total power is equal to P= 3 W1.
Select one:
True
False
Don't Use Chat GPT Will Upvote And Give Handwritten Solution Please
Chapter 13 Solutions
Electrical Transformers and Rotating Machines
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In this part why is there value of 2000 and 1000 here?arrow_forwardA circuit contains two un-equal resistances in series Select one: O A. larger potential develops in smaller resistance O B. current is same in both large current flows in larger resistor OD. Potential difference across each is samearrow_forwardA 772 range voltmeter is having an accuracy of + 0.11% of FSD. Calculate the following for the given M1 =677 volt and M2=732 volt. Accuracy= For M1 reading : Maximum Acceptable Value = Minimum Acceptable value = % Error =arrow_forward
- Question 2 Calculate the current i1 if R1 = 7 Ohms, R2 = 6 Ohms. R3 = 3 Ohms, R4 = 8 Ohms, and Vs = 39 Volts. R1 ww Vs R2 R3 R4 ww 券 Nex Su No new data to save. Last checked at 2:30am ww wwarrow_forwardThe windscreen washers of an old car don't work (W = 0). This could be for two reasons: the windscreen fluid tank is empty (E = 1) or the tube is has a blockage (B = 1). Being an old car, the light to indicate that the windscreen fluid tank is empty only comes on (L = 1) 75% of the time. It will sometimes comes on even if the tank has some fluid in it, with probability 0.25. Of course the tube could be both blocked and the tank empty. (a) Draw the Bayesian network describing the scenario just described, and express the joint probability in factorised form, defining appropriate variables.arrow_forwardWhat is the resistance of gauge no. 10 copper wire (diameter of 0.026 m), which is 1km long at 20 degrees Celcius?arrow_forward
- Find the value of the currents I1 and 12. 100 ohm 5V 5V 100 ohm 12 O a. 1=-0.3A, 12=-0.1A O b. 11=0.3A, 12=0.1A Oc. 11=0.05A, 12=0.1A O d. 11=0.1A, 12=0.2Aarrow_forwardThe following data were obtained on a 50 kVA 2400/120 V transformer: Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer : Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.arrow_forwardQuestion 7 In no-load phasor diagram of the transformer, the core loss component current is with primary voltage. Not yet answered O out of phase & parallel Marked out of O Parallel & in phase 1.00 P Flag question O in phase O Perpendicular & in phase Question 8 In an A.C. circuit, the power measured by using wattmeter is power. Not yet answered Marked out of 1.00 P Flag question Question 9 In step up transformer, secondary turns are less than primary turns. Not yet answered Marked out of Select one: 1.00 P Flag question O True O Falsearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning