The velocity of the oxygen at nozzle exit by treating the oxygen as an ideal gas and using enthalpy departure charts.

Answer to Problem 77P
The exit velocity of the nozzle by treating the oxygen as an ideal gas is
The exit velocity of the nozzle by using enthalpy departure charts is
Explanation of Solution
Write the general formula energy balance equation for closed system.
Here, rate of energy transfer into the system is
At the steady state, the rate of change of net energy of the system is zero.
Since the inlet velocity is negligible and the Equation (I) is rewritten as follows for the nozzle.
Here, inlet velocity is
Write the formula for change in entropy equation
Here, universal gas constant is
Write the change in enthalpy equation per mole basis.
Here, Ideal enthalpy at final state is
Write the formula for change in enthalpy equation in mass basis.
Here, molar mass is
Calculate the reduced temperature
Here, critical temperature is
Calculate the reduced pressure
Here, critical pressure is
Calculate the reduced temperature
Here, critical temperature is
Calculate the reduced pressure
Here, critical pressure is
Write the formula for change in enthalpy
Here, change in enthalpy of ideal gas is
Refer Table A-19E, “Ideal properties of oxygen”.
The inlet enthalpy
Refer table A-1E, “Molar mass, gas constant and critical properties table”.
The molar mass of oxygen is
The critical temperature of oxygen is
The critical pressure of oxygen is
The gas constant of oxygen is
Conclusion:
Substitute
Refer Table A-19E, “Ideal properties of oxygen”.
The exit enthalpy
Substitute
Substitute
Equation (V).
Substitute
Thus, exit velocity of the nozzle by treating the oxygen as an ideal gas is
Substitute 1060 R for
Substitute
Refer the table A-15E, “Nelson-Obert generalized compressibility chart”.
Obtain the enthalpy departure factor
Substitute 802 R for
Substitute
Refer the table A-15E, “Nelson-Obert generalized compressibility chart”.
Obtain the enthalpy departure factor
Substitute
Substitute
Thus, the exit velocity of the nozzle by using enthalpy departure charts is
Want to see more full solutions like this?
Chapter 12 Solutions
THERMODYNAMICS LLF W/ CONNECT ACCESS
- Design and assemble on the fluidsim (or a draft) the Hydraulic Drive Circuit, with the following characteristics: (a) Sequential operation, pressure, for the advance and return of the cylinders (according to the proper operation for the device) controlled by a directional 4x3 way, closed center; (b) Speed control for the cylinders, according to the load signal; (c) Pressure counterbalance for cylinder A, in order to compensate for the weight of the assembly.arrow_forwardThis is an old exam practice question. The answer is Pmax = 218.8 kN normal stress governs but why?arrow_forwardMoist air initially at T₁ = 140°C, p₁ = 4 bar, and p₁ = 50% is contained in a 2.0-m³ closed, rigid tank. The tank contents are cooled to T₂ 35°C. Step 1 Determine the temperature at which condensation begins, in °C.arrow_forward
- Air at T₁ = 24°C, p₁ = 1 bar, 50% relative humidity enters an insulated chamber operating at steady state with a mass flow rate of 3 kg/min and mixes with a saturated moist air stream entering at T2=7°C, p₂ = 1 bar. A single mixed stream exits at T3-17°C, p3=1 bar. Neglect kinetic and potential energy effectsarrow_forwardHand calculation of cooling loadarrow_forwardAn HEV has a 24kW battery. How many miles can it go on electricity alone at 40 mph on a flat straight road with no headwind? Assume the rolling resistance factor is 0.018 and the Coefficient of Drag (aerodynamic) is 0.29 the frontal area is 2.25m^2 and the vehicle weighs 1618 kg.arrow_forward
- As shown in the figure below, moist air at T₁ = 36°C, 1 bar, and 35% relative humidity enters a heat exchanger operating at steady state with a volumetric flow rate of 10 m³/min and is cooled at constant pressure to 22°C. Ignoring kinetic and potential energy effects, determine: (a) the dew point temperature at the inlet, in °C. (b) the mass flow rate of moist air at the exit, in kg/min. (c) the relative humidity at the exit. (d) the rate of heat transfer from the moist air stream, in kW. (AV)1, T1 P₁ = 1 bar 11 = 35% 120 T₂=22°C P2 = 1 bararrow_forwardThe inside temperature of a wall in a dwelling is 19°C. If the air in the room is at 21°C, what is the maximum relative humidity, in percent, the air can have before condensation occurs on the wall?arrow_forwardThe inside temperature of a wall in a dwelling is 19°C. If the air in the room is at 21°C, what is the maximum relative humidity, in percent, the air can have before condensation occurs on the wall?arrow_forward
- ###arrow_forwardFind the closed loop transfer function and then plot the step response for diFerentvalues of K in MATLAB. Show step response plot for different values of K. Auto Controls Show solution for transform function and provide matlab code (use k(i) for for loop NO COPIED SOLUTIONSarrow_forwardThis is an old practice exam. The answer is Ta-a = 4.615 MPa max = 14.20 MPa Su = 31.24 MPa Sus = 10.15 MPa but why?arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY