Understanding Motor Controls
4th Edition
ISBN: 9781337798686
Author: Stephen L. Herman
Publisher: Delmar Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 12, Problem 4RQ
Referring to Figure 12–14, assume that the normally open 2M contact located between wire numbers 23 and 29 is welded closed. Also assume that none of the motors are running. What would happen if:
- a. The number 2 push button was to be pressed before the number 1 push button?
- b. The number 1 push button was to be pressed first?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
All terminals have a defined wire size range. If I had a wire of 2.0mm / 15 AWG, what terminal should I use?
A. Red insulated terminal.
B. Blue insulated terminal.
C. Yellow insulated terminal.
D. It doesn’t matter as all these answers are correct.
Boxes (or certain production parts) are moved by a double-acting cylinder away from a gravity-feed magazine towards an assembly device. A push button and a pedal switch are to be incorporated in the circuit. The cylinder is to move out when either of these is actuated. The return stroke is actuated by the cylinder rod after it reaches the end of the forward stroke.
Draw the pneumatic circuit diagram using ISO symbols and connecting the ports with solid lines.
Select the proper choice(s) for each of the following statements:
1) To control single-acting cylinder we just need:
double-acting cylinder we should use
A2/2-way, 5/2-way,
(C) 3/3-way, 3/4-way,
2) In
DCV.
(B) 3/2-way, 4/2-way,
(D) 4/3-way, 3/2-way.
mid poistion of DCV, we can move cylinder piston rod freely without
resistance by hand.
(A) working ports are exhausted,
(C) working ports are pressurized,
3) In pneumatics we use
A Compressor
(B) Pump,
DCV, while to control the
4) Quick exhaust valve is used to
(A) increase the cylinder return speed.
(C) meter-out the cylinder speed
(B) all ports are closed.
no one of these options.
to obtain high pressure air.
(C) Turbine,
(D) pressure relief valve.
(B) meter-in the cylinder speed,
(D) increase the cylinder extending speed.
6) Meter-in of cylinder movement is used to control the
Afluid that enters the hydraulic cylinder,
(B) fluid that exits the hydraulic cylinder,
(C) fluid that enters the DCV
(D) fluid that exits the DCV.
5) One of the…
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the schematic diagram in Figure 318. Assume that the motor is not running. When the third speed push button is pressed, the motor starts in its lowest speed. After a delay of 3 seconds, the motor accelerates to second speed and 3 seconds later to third speed. After a period of about 1 minute, the fourth speed push button is pressed, but the motor does not accelerate to fourth speed. Which of the following could cause this problem? a. Control relay CR2 coil is open. b. S2 contactor coil is open. c. CR3 coil is shorted. d. S3 contactor coil is open.arrow_forwardRefer to the circuit shown in Figure 16-11. Assume that the platform is located on the lower floor. When the UP push button is pressed, the platform rises. When the platform reaches the upper floor, however, the pump does not turn off but continues to run until the overload relay opens the overload contacts. Which of the following could cause this problem? a. The solenoid valve opened when limit switch LS1 opened. b. The UP push button is shorted. c. Limit switch LS1 did not open its contacts. d. Limit switch LS2 contacts did not reclose when the platform began to rise.arrow_forwardRefer to the circuit shown in Figure 16-11. Assume that the platform is located on the bottom floor. When the UP push button is pressed the pump motor does not start. Which of the following could not cause this problem? The contacts of limit switch LS1 are open. The contacts of limit switch LS2 are open. Motor starter coil M is open. The overload contact is open.arrow_forward
- Assume that all three motors shown in Figure 12–14 are running. Now assume that the STOP button is pressed and motors #1 and #2 stop running, but motor #3 continues to operate. Which of the following could cause this problem? STOP button is shorted. The 2M contact between wire numbers 31 and 32 is hung closed. The 3M load contacts are welded shut. The normally open 3M contact between wire numbers 23 and 31 is hung closed.arrow_forwardWhat pin numbers are connected to the coil of an 8-pin control relay?arrow_forwardRefer to the schematic in Figure 7-10. Assume that when the START button is pressed, the control transformer fuse blows. What is the most likely cause of this trouble? Figure 7-10 Numbers are placed beside all components.arrow_forward
- Refer to Figure 21–1 to answer the following questions. Assume that HOA SW 120 has been set in the auto position. List four ways by which coil CR-8 could be energized.arrow_forwardAn 11-pin control relay contains three sets of single-pole double throw contacts. List the pin numbers by pairs that can be used as normally open contacts.arrow_forwardRefer to the circuit shown in Figure 97. Assume that when the forward push button is pressed the motor does not start, but when the reverse push button is pressed the motor will start in the reverse direction. When the stop button is pressed the motor stops running. Which of the following could NOT cause this problem? a. The forward push button is defective. b. The F starter coil is open. c. The overload auxiliary contact is open. d. The normally closed R contact is open.arrow_forward
- How do you check for an open armature winding?arrow_forwardRefer to the circuit shown in Figure 33–7. When the low speed push button is pressed, the motor begins to run in low speed. When the high speed push button is pressed, the motor stops running. Which of the following could cause this problem? The 1L contactor coil is open. H contactor coil is open. PR relay coil is open. The 2L contactor coil is open.arrow_forwardName two requirements that must be met before a motor can be used for wye-delta starting.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781305498129Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781305498129
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Differences between Temporary Joining and Permanent Joining.; Author: Academic Gain Tutorials;https://www.youtube.com/watch?v=PTr8QZhgXyg;License: Standard Youtube License