Concept explainers
The five common types of cable used in residential wiring along with their NEC® article for each cable.
Explanation of Solution
The common types of cable used in residential wiring are as follows:
- Nonmetallic sheathed cable
- Power and control tray cable
- Underground feeder cable
- Armored cable
- Metal-clad cable
Nonmetallic sheathed cable
The installation specifications for nonmetallic sheathed cable are covered in Article 334 of the NEC®. Type NM cable is permitted to be used in one- and two-family houses which include detached or attached garages and storage buildings, according to Section 334.10(1).
Power and control tray cable
The National Electrical Code now enables Type TC cable to be used in one- and two-family dwelling units under Section 336.10(9). Type TC cable is defined as a factory assembly of two or more insulated conductors, with or without associated grounding conductors, underneath a nonmetallic jacket, as defined in Section 336.2.
Underground feeder cable
Type UF cable can be utilized in house wiring for direct burial purposes or for wiring scenarios where nonmetallic sheathed cable would ordinarily be utilized, according to Article 340 of the NEC®. Section 300.5 must be applied for underground installation standards.
Armored cable
Armored cable, often known as "BX" cable by electricians, can be used in a house either concealed or exposed. Exposed Type AC wire must closely follow the building finish surface or be attached to running boards according to Section 320.15.
Metal-clad cable
The other type of cable where some electricians use for house wiring is metal-clad cable. The NEC® specifies certain installation criteria for Type MC Cable in Article 330.
Conclusion:
The five common types of cable used in residential wiring are nonmetallic sheathed cable, power and control tray cable, underground feeder cable, armored cable and metal-clad cable.
Want to see more full solutions like this?
Chapter 11 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
- List the minimum trade size of Type EMT for each of the following applications. Assume the use of conductors with THHN insulation. (Objective 12-1) a. Six 14 AWG _______ b. Six 12 AWG ______ c. Three 10 AWG ______ d. Four 8 AWG _____arrow_forwardDescribe how a white Insulated conductor in a cable assembly is reidentified as an ungrounded hot conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forward
- Describe the purpose of an LB conduit body used in a residential service entrance Installation that uses electrical conduit. (Objective 8-1)arrow_forwardName and describe three cable types that can be used in residential electrical installations. (Objective 2-5)arrow_forwardThe most often used category-rated UTP cable for voice and data wiring from various outlets back to the service center or other distribution device in a residential application is______. (Objective 16-3)arrow_forward
- Describe how a conductor that is larger than 6 AWG can be identified as a grounding conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardAlthough it is not a specific requirement, most electricians feel that the best place to start a cable run for a branch circuit is at the service panel or subpanel. Explain why this is so. (Objective 11-3)arrow_forwardName the ampacity for the following copper conductors according to Table 310.15(B) (16): (Objective 6-4) a. 10 AWG THW amps _____ amps b. 8 AWG THWN amps_______ amps c. 1 AWG THHN amps ______ amps d. 4/0 TW amps ______ ampsarrow_forward
- Describe how an insulated grounded conduct or Larger than 6 AWG is Identified. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardName the standard sizes of circuit breakers up to and including 100 amperes. This information is found in NEC NEC Section____________.(Objective 6-2)arrow_forwardIf Type SER service entrance cable is used by an electrician to feed a subpanel from a main panel, the cable must be secured within _________of the panel enclosures and at Intervals not exceeding___________. Name the NEC section that states this requirement. (Objective 8-7)arrow_forward
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage LearningResidential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781285852225Author:Gregory W FletcherPublisher:Cengage Learning