Name the types of receptacles and switches, and mention the number of receptacles and switches that are used in circuit A14.
Answer to Problem 1R
The types of switches and receptacles used in circuit A14 are listed, and totally four switches and one receptacle are used in circuit A14.
Explanation of Solution
Discussion:
Circuit A14 is a 15-ampere branch circuit that delivers power to the hallway receptacle, the hallway lighting, and the vanity lighting used in bathrooms.
The types of switches and receptacles used in the hallway and bathrooms (Circuit A14) are listed as follows:
- • One receptacle in the hall.
- • One single-pole switch in the hall bathroom.
- • One single-pole switch in the master bathroom.
- • Two 3-way switches in the hall.
Therefore, from the above list, totally four switches and one receptacle are used in the hallway and bathrooms. Hence, a total of five numbers are used in Circuit A14.
Refer to NEC 210.11(C)(3), the receptacles used in the bathrooms are supplied by separate 20-ampere branch circuits A22 and A23.
Conclusion:
Thus, the types of switches and receptacles used in circuit A14 are listed, and totally four switches and one receptacle are used in circuit A14.
Want to see more full solutions like this?
Chapter 10 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
- 1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward
- iF AN AMMETER WAS CONNECTED BETWEEN SWITCH1 AND POTENTIOMETER R1, HOW MUCH CURRENT WOULD IT INDICATE AT E(min) and E(max) IE(min)=__________________________mAdc IE(max)=__________________________mAdcarrow_forwardKVLLoop abfea: __________________________________________________Loop cdhgc: __________________________________________________Loop bcgfb: ___________________________________________________arrow_forwardIf a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forward
- An isolator is used to: Select one: a. To be mounted on towers for insulation purpose b. All of the above c. to disconnect part of the system for maintenance from live circuit d. Insulate the wires to avoid electrocution and short circuits Clear my choicearrow_forwardElectrical plants Define the terms "Main column ." " Line ." " Protection earth " and " Operating eartharrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward
- 6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steelarrow_forwardWhat assumptions can you make regarding the following receptacle wiring? Check all that apply. White neutral wire Grounding screw Brass screw terminal Silver screw terminal Black hot wire Red hot wire Grounding wires Grounding screw terminal O device is at end-of-run device box does not need a ground connection this is a split-circuit receptacle neutral side receptacle tab must be removedarrow_forwardoleg is using a multimeter to test the circuit branch he's just installed. after turning off the current to the circuit at the service panel, he'll first attach one probe to the ----- in the end of the run. a. black wire b. box c. white wire d. ground wire Please answer with explanation In typing formatarrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT