Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN: 9781305387102
Author: Kreith, Frank; Manglik, Raj M.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 10, Problem 10.6P
Mot water is used to heat air in a double-pipe heat exchanger as shown in the following sketch. If the
heat transfer coefficients on the water side and on the air side are
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
EXAMPLE 3
Consider the heat exchanger
finned-tube, cross-flow heat exchanger with a gas-side overall
heat transfer coefficient and area of 100 W/m² · K and 40 m²,
respectively. The water flow rate and inlet temperature remain at
1 kg/s and 35C. However, a change in operating conditions for
the hot gas generator causes the gases to now enter the heat
exchanger with a flow rate of 1.5 kg/s and a temperature of
250C. What is the rate of heat transfer by the exchanger, and
what are the gas and water outlet temperatures?
that is, a
1² .
Blowtorch is used to connect the two pipes together. Length of the pipe
section shown is 150 cm with an inner diameter of 85 cm. The thickness of
the pipe wall is 4 mm. The conductivity of the pipe section is 167 W/m^2K.
Environment has a temperature of 30 C and convective heat transfer
coefficient of 28 WI(mC), find the required heat transfer to join the pipe
sections at 220 C? HINT: Assume that the welding section is the base
plate and the pipe is 1D extended surface (fin) symmetric about the torch
melting line. Heat transfer happens by conduction along the pipe
thickness in horizontal direction and by convection to the environment.
Length
thickness
Torch melting line
Blowtorch is used to connect the two pipes together. Length of the pipe
section shown is 150 cm with an inner diameter of 85 cm. The thickness of
the pipe wall is 4 mm. The conductivity of the pipe section is 167 Wim^2K.
Environment has a temperature of 30 C and convective heat transfer
coefficient of 28 WI(mC), find the required heat transfer to join the pipe
sections at 220 C? HINT: Assume that the welding section is the base
plate and the pipe is 1D extended surface (fin) symmetric about the torch
melting line. Heat transfer happens by conduction along the pipe
thíckness in horizontal direction and by convection to the environment.
Length
thickness
Torch melting line
200 W
275 W
none
314 W
453 W
Chapter 10 Solutions
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
Ch. 10 -
10.1 In a heat exchanger, as shown in the...Ch. 10 - Prob. 10.2PCh. 10 -
10.3 A light oil flows through a copper tube of...Ch. 10 - Prob. 10.4PCh. 10 - Water flowing in a long, aluminum lube is to be...Ch. 10 - Mot water is used to heat air in a double-pipe...Ch. 10 - Prob. 10.7PCh. 10 -
10.8 The heat transfer coefficient of a copper...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Determine the rate of heat transfer per meter length to a light oil flowing through a 2.5-cm-ID, 60-cm-long copper tube at a velocity of 0.03 m/s. The oil enters the tube at 16C, and the tube is heated by steam condensing on its outer surface at atmospheric pressure with a heat transfer coefficient of 11.3 kW/m K. The properties of the oil at various temperatures are listed in the following table: Temperature, T(C) 15 30 40 65 100 (kg/m3) 912 912 896 880 864 c(kJ/kgK) 1.80 1.84 1.925 2.0 2.135 k(W/mK) 0.133 0.133 0.131 0.129 0.128 (kg/ms) 0.089 0.0414 0.023 0.00786 0.0033 Pr 1204 573 338 122 55arrow_forward10.1 In a heat exchanger, as shown in the accompanying figure, air flows over brass tubes of 1.8-cm 1D and 2.1-cm OD containing steam. The convection heat transfer coefficients on the air and steam sides of the tubes are , respectively. Calculate the overall heal transfer coefficient for the heal exchanger (a) based on the inner tube area and (b) based on the outer tube area.arrow_forward3.14 A thin-wall cylindrical vessel (1 m in diameter) is filled to a depth of 1.2 m with water at an initial temperature of 15°C. The water is well stirred by a mechanical agitator. Estimate the time required to heat the water to 50°C if the tank is suddenly immersed in oil at 105°C. The overall heat transfer coefficient between the oil and the water is , and the effective heat transfer surface is .arrow_forward
- A heat recovery device involves transferring energy from the hot flue gases passing through an annular region to pressurized water flowing through the inner tube of the annulus. The inner tube has inner and outer diameters of 24 and 30 mm and is connected by 8 struts to an insulated outer tube of 40-mm diameter. Each strut is 3 mm thick and is integrally fabricated with the inner tube from carbon steel (k = 50W/m-K). E1 = 3 mm D. Water Gas Consider conditions for which water at 300 K flows through the inner tube at 0.161 kg/s while flue gases at 800 K flow through the annulus, maintaining a convection coefficient of 100 W/m2-K on both the struts and the outer surface of the inner tube. What is the rate of heat transfer per unit length of tube from gas to the water? Use the Dittus-Boelter equation to obtain the water-side convection coefficient. Determine the rate of heat transfer per unit length of tube from gas to the water, in W/m. i W/m Physical Properties Mathematical Functionsarrow_forwardA heat exchanger is to be designed to condense 8 kg/sec of an organic liquid (tsat=80°C, hfg=600 KJ/kg) with cooling water available at 15°C and at a flow rate of 60 kg/sec. The overall heat transfer coefficient is 480 W/m2 -°C calculate: a) The number of tubes required. The tubes are to be of 25 mm outer diameter, 2 mm thickness and 4.85 m length b) The number of tube passes. The velocity of the cooling water is not to exceed 2 m/sec.arrow_forwardcan you please please work it all outarrow_forward
- Q1: A shell-and-tube heat exchanger having one shell pass and four tube passes is shown schematically in the following sketch. The fluid in the tubes enters at 200°C and leaves at 100°C. The temperature of the fluid is 20°C entering the shell and 90°C leaving the shell. The overall heat transfer coefficient based on the surface area of 12 m² is 300 W/m² K. Calculate the heat transfer rate between the fluids. Tube fluid 200 °C Tube fluid 100 °C Shell fluid 90 °C W 41 Shell fluid 20°Carrow_forwardYour second customer wants to choose a parallel-flow-plate-type heat exchanger that contains two fluids (oil and water) separated by a thin metal sheet as shown in figure 1 for cooling the lubricating oil. The heat exchanger is insulated by a 130-mm glass fiber insulation (paper faced, 28 kg/m3 ). The heat transfer coefficients of water and oil are 1200 and 900 W/m2 °C, respectively. Figure 1: A parallel-flow-plate-type heat exchanger. Your task to help your costumer by doing the following steps: STEP 1 The flow rate of cooling water is 0.2 kg/s, and the flow rate of oil the is 0.1 kg/s. Also, the oil and water enter at temperatures of 100 and 30°C, respectively, and the outlet temperature of the oil is 40°C. If the top surface of the heat exchanger is exposed to an atmospheric air (T=10°C) that is parallel to the flows and maintains a heat transfer coefficient of h = 70 W/m2 .K, which includes the effects of radiation, help your customer to calculate the heat…arrow_forwardDetermine the length needed for a simple concentric-tube, parallel flow heat exchanger to transfer heat from hot water to cold water at a rate of 900 W. The heat exchanger consists of two Type K copper (k=386 W/m-degC) tubes. The smaller tube has an inside diameter of 49.8 mm and an outside diameter of 54.0 mm. Assume that both film coefficients are equal to 100 W/sq.m.-degC. The hot water enters at 90 degC and leaves at 50 degC, and the cold water enters at 10 degC and leaves at 40 degC.arrow_forward
- Engine oil at 0.3 kg/s flow rate (cp=2100 J/kg°C) 2 cmat a temperature of l30°C in a thin-walled copper pipe in diameterit will be heated from 20°C to 60°C by condensing steam outside.Total heat transfer coefficient 650 W / m2For ° C, heat transferpipe required to achieve the speed and speed of this heat transferfind the length.arrow_forwardQ1: A shell-and-tube heat exchanger having one shell pass and four tube passes is shown schematically in the following sketch. The fluid in the tubes enters at 200°C and leaves at 100°C. The temperature of the fluid is 20°C entering the shell and 90°C leaving the shell. The overall heat transfer coefficient based on the surface area of 12 m² is 300 W/m² K. Calculate the heat transfer rate between the fluids. +4 Tube fluid 200 °C Tube fluid 100 °C Shell fluid 90 °℃ M 41: Shell fluid 20°Carrow_forwardA cross flow plate fin compact heat exchanger is to be used for this heat recovery application. We wish to select a heat exchanger which will yield ε = 0.75, using stainless steel fin materials. Calculate the UA required to obtain ε = 0.75. Calculate UA by ε-NTU methods and state why the LMTD method is difficult to use. For the ε -NTU methods, first use the graphical method and then the equation.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
How Shell and Tube Heat Exchangers Work (Engineering); Author: saVRee;https://www.youtube.com/watch?v=OyQ3SaU4KKU;License: Standard Youtube License