Fundamentals of Electromagnetics with Engineering Applications
1st Edition
ISBN: 9780470105757
Author: Stuart M. Wentworth
Publisher: Wiley, John & Sons, Incorporated
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 10, Problem 10.27P
A four-port “20-dB coupler” is specified as having 20-dB coupling, 50-dB isolation, and 0.25 dB of insertion loss. If 100 mW of power is input, calculate the power out of the other three ports. Assume all ports are terminated in matched loads.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
"I need something clear written by hand
with steps."
Find Laplace transform and the corresponding ROC for
x(t) = e−3sin(2t) u(t)dt
Three similar coils, connected in star, take a total
power of 1.5 kW, at a power factor of 0.2, from a
three-phase, 400 V, 50 Hz supply. Calculate: (a) the
resistance and inductance of each coil; (b) the line
currents if one of the coils is short-circuited.
(a) Three 20 µF capacitors are star-connected across
a 400 V, 50 Hz, three-phase, three-wire supply.
Calculate the current in each line. (b) If one of the
capacitors is short-circuited, calculate the line cur
rents. (c) If one of the capacitors is open-circuited,
calculate: the line currents and the p.d. across each
of the other two capacitors.
ANS:
1.525 A; 2.64 A, 2.64 A, 4.57 A; 1.32 A, 1.32 A, 0;
210 V
Chapter 10 Solutions
Fundamentals of Electromagnetics with Engineering Applications
Ch. 10 - A matching network consists of a length of a...Ch. 10 - Design an L-section matching network to match a...Ch. 10 - Design an L-section matching network to match an...Ch. 10 - Design an L-section matching network to match a...Ch. 10 - Suppose you want to match a 100 line to a load...Ch. 10 - Prob. 10.7PCh. 10 - Prob. 10.8PCh. 10 - Prob. 10.9PCh. 10 - Prob. 10.10PCh. 10 - Suppose the L-section matching network of Example...
Ch. 10 - Find the scattering matrices for the simple...Ch. 10 - Cut a 50- T-line and insert a series 50- resistor...Ch. 10 - Prob. 10.14PCh. 10 - A series capacitor of value C=2.0pF is inserted in...Ch. 10 - A series inductor of value L=3.5nH is inserted in...Ch. 10 - Prob. 10.17PCh. 10 - The scattering matrix (assuming a 50- impedance...Ch. 10 - Three T-lines with the same characteristic...Ch. 10 - Consider a three-port network that is matched at...Ch. 10 - Prob. 10.21PCh. 10 - Calculate the insertion loss and the VSWR for the...Ch. 10 - Prob. 10.23PCh. 10 - Verify the scattering matrix (10.27) for the...Ch. 10 - Prob. 10.25PCh. 10 - Prob. 10.26PCh. 10 - A four-port 20-dB coupler is specified as having...Ch. 10 - Suppose the coupling for an ideal symmetrical...Ch. 10 - Suppose to port 1 of an ideal ring hybrid coupler...Ch. 10 - Prob. 10.30PCh. 10 - Prob. 10.31PCh. 10 - Prob. 10.32PCh. 10 - Suppose you join a pair of quadrature hybrid...Ch. 10 - Prob. 10.34PCh. 10 - Prob. 10.35PCh. 10 - Prob. 10.36PCh. 10 - Prob. 10.37PCh. 10 - Prob. 10.38PCh. 10 - Prob. 10.39PCh. 10 - Prob. 10.40PCh. 10 - Starting with the Figure 10.28b circuit...Ch. 10 - Starting with the Figure lO.28b circuit...Ch. 10 - Prob. 10.43PCh. 10 - Starting with the Figure 10.28a circuit...Ch. 10 - Prob. 10.45PCh. 10 - For Problem 10.45, (a) design open-ended shunt...Ch. 10 - Prob. 10.47PCh. 10 - Prob. 10.48PCh. 10 - Prob. 10.49PCh. 10 - Prob. 10.50PCh. 10 - Prob. 10.51PCh. 10 - Referring to Example 10.21 and Figure 10.48,...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Explain the advantages of three-phase supply for distribution purposes. (b) Assuming the relationship between the line and phase values of currents and voltages, show that the active power input to a three-phase balanced load is √3VI cos φ, where V and I are line quantities. (c) Three similar inductors, each of resistance 10 Ω and inductance 0.019 H, are delta-connected to a three-phase, 400 V, 50 Hz sinusoidal supply. Calcu late: the value of the line current; the power factor and the active power input to the circuit. ANS: 59.5 A, 0.858 lag, 35.5 kWarrow_forwardnot use ai pleasearrow_forwardA three-phase, 400 V, star-connected motor has an output of 50 kW, with an efficiency of 90 per cent and a power factor of 0.85. Calculate the line current. Sketch a phasor diagram showing the voltages and currents. If the motor windings were connected in mesh, what would be the correct voltage of a three phase supply suitable for the motor? ANS: 90.8 A, 240 Varrow_forward
- Don't use ai to answer I will report you answerarrow_forwardShow with the aid of a phasor diagram that for both star- and delta-connected balanced loads, the total active power is given by √3VI cos φ, where V and I are the line values of voltage and current respectively and φ is the angle between phase values of voltage and current. A balanced three-phase load consists of three coils, each of resistance 4 Ω and inductance 0.02 H. Determine the total active power when the coils are (a) star-connected, (b) delta-connected to a 400 V, three phase, 50 Hz supply. ANS:11.56 kW, 34.7 kWarrow_forwardThe load connected to a three-phase supply comprises three similar coils connected in star. The line currents are 25 A and the apparent and active power inputs are 20 kVA and 11 kW respectively. Find the line and phase voltages, reactive power input and the resistance and reactance of each coil. If the coils are now con nected in delta to the same three-phase supply, calculate the line currents and the active power taken. ANS : 462 V, 267 V, 16.7 kvar, 5.87 Ω, 8.92 Ω; 75 A, 33 kWarrow_forward
- A three-phase delta-connected load, each phase of which has an inductive reactance of 40 Ω and a resistance of 25 Ω, is fed from the secondary of a three-phase star-connected transformer which has a phase voltage of 230 V. Draw the circuit diagram of the system and calculate: (a) the current in each phase of the load; (b) the p.d. across each phase of the load; (c) the current in the transformer secondary windings; the total active power taken from the supply and its power factor.arrow_forwardDerive the numerical relationship between the line and phase currents for a balanced three-phase delta connected load. Three coils are connected in delta to a three-phase, three-wire, 400 V, 50 Hz supply and take a line current of 5 A 0.8 power factor lagging. Calculate the resistance and inductance of the coils. If the coils are star-connected to the same supply, calculate the line current and the total power. Calculate the line cur rents if one coil becomes open-circuited when the coils are connected in star. Ans: 110.7 Ω, 0.264 H; 1.67 A, 926 W; 1.445 A, 1.445 A, 0arrow_forwardDerive, for both star- and delta-connected systems, an expression for the total power input for a balanced three-phase load in terms of line voltage, line current and power factor. The star-connected secondary of a transformer supplies a delta-connected motor taking a power of 90 kW at a lagging power factor of 0.9. If the volt age between lines is 600 V, calculate the current in the transformer winding and in the motor winding. Draw circuit and phasor diagrams, properly labelled, showing all voltages and currents in the transformer secondary and the motor. ANS: . 96.2 A, 55.6 Aarrow_forward
- Deduce the relationship between the phase and the line voltages of a three-phase star-connected generator. If the phase voltage of a three-phase star-connected generator is 200 V, what will be the line voltages: (a) when the phases are correctly connected; (b) when the connections to one of the phases are reversed? ans: 346 V; 346 V, 200 V, 200 Varrow_forwardQ2: Given a discrete sequence x(n) = [1,-1,2,4, 1, 3,-1,1] and its spectrum X(k): i. Show that: X(k) =G(k)+WH(k) k=0,1,2,3,4,5,6,7 where G(k) = DFT[g(n)] and H(k) = DFT[h(n)], g(n) and h(n) are even and odd components of x(n) respectively. ii. Compute G(k) and H(k) using the method of computation of DFTS of two real sequences. (15 marks)arrow_forwardQ2: Given a discrete sequence x(n) = [1,-1,2,4, 1, 3,-1,1] and its spectrum X(k): i. Show that: X(k) = G(k)+WH(k) k = 0,1,2,3,4,5,6,7 where G(k) = DFT[g(n)] and H(k) = DFT[h(n)], g(n) and h(n) are even and odd components of x(n) respectively. ii. Compute G(k) and H(k) using the method of computation of DFTS of two real sequences.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Lecture 4b -- Transmission Line Parameters; Author: EMPossible;https://www.youtube.com/watch?v=naG572ZnXqw;License: Standard Youtube License