You are tasked to design a system that will monitor and regulate the air flow in a hospital ward. The design should take inputs from all of the following four sensors:  Sensor A has been set to trigger when the windows in the ward are open.  Sensor B has been set to trigger when the relative level of moisture in the air has exceeded 30%.  Sensor C is an anemometer and has been set to trigger when the rate of air flow at the ventilation grills has dropped below 20 m/s.  Sensor D is a thermometer and has been set to trigger when the ambient temperature in the ward has exceeded 20°C.  The system should operate based on the following conditions: • If the windows in the ward are closed, the system should switch on the air conditioning unit automatically if 1) the temperature is over 20°C and airflow rate is less 20m/s, or 2) temperature is over 20°C and humidity over 30%. • If the windows in the ward are open and the ambient temperature is over 20°C, the system should generate an alert.  a) Based on the information given above, provide a Truth Table for the system. For both the air conditioning unit and the alert system, use a Karnaugh Map to obtain a Boolean Expression for each case.

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question

You are tasked to design a system that will monitor and regulate the air flow in a hospital ward. The design should take inputs from all of the following four sensors: 

Sensor A has been set to trigger when the windows in the ward are open. 

Sensor B has been set to trigger when the relative level of moisture in the air has exceeded 30%. 

Sensor C is an anemometer and has been set to trigger when the rate of air flow at the ventilation grills has dropped below 20 m/s. 

Sensor D is a thermometer and has been set to trigger when the ambient temperature in the ward has exceeded 20°C. 

The system should operate based on the following conditions:

• If the windows in the ward are closed, the system should switch on the air conditioning unit automatically if 1) the temperature is over 20°C and airflow rate is less 20m/s, or 2) temperature is over 20°C and humidity over 30%.

• If the windows in the ward are open and the ambient temperature is over 20°C, the system should generate an alert. 

a) Based on the information given above, provide a Truth Table for the system. For both the air conditioning unit and the alert system, use a Karnaugh Map to obtain a Boolean Expression for each case. 

Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY