Water at a flow rate of 5 kg / s in a tube bundle heat exchanger from 80 ° C to 100 ° C will be heated. Heating operation 250 kN / m2 It is provided by the condensation of a steam. Heat exchanger It consists of two pipes. The pipe outer diameter is 32 mm. Total heat transfer coefficient 1752 W / m2 Take it as ° C and calculate the required pipe length.
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
Water at a flow rate of 5 kg / s in a tube bundle heat exchanger from 80 ° C to 100 ° C will be heated. Heating operation 250 kN / m2 It is provided by the condensation of a steam. Heat exchanger It consists of two pipes. The pipe outer diameter is 32 mm. Total heat transfer coefficient 1752 W / m2 Take it as ° C and calculate the required pipe length.
Step by step
Solved in 2 steps with 2 images