Two 6600/250-V transformers have the following short-circuit characteristics: Applied voltage 200 V, current 30 A, power input 1,20 W for one of the transformers; the corresponding data for the other transformer being 120 V, 20 A, and 1,500 W. All value are measured on the H.V. side with the L.V. terminals short-circuited. Find the approximate current and the power factor of each transformer when working in parallel with each other on the high and low voltage sides and taking a total load of 150 kW at a p.f. c 0.8 lagging from the high voltage bus bars.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
Two 6600/250-V transformers have the following short-circuit characteristics: Applied voltage 200 V, current 30 A, power input 1,200 W for one of the transformers; the corresponding data for the other transformer being 120 V, 20 A, and 1,500 W. All value are measured on the H.V. side with the L.V. terminals short-circuited. Find the approximate current and the power factor of each transformer when working in parallel with each other on the high and low voltage sides and taking a total load of 150 kW at a p.f. of 0.8 lagging from the high voltage bus bars.
Two 6600/250-V transformers have the following short-circuit characteristics: Applied voltage 200 V, current 30 A, power input 1,200
W for one of the transformers; the corresponding data for the other transformer being 120 V, 20 and 1,500 W. All value are
measured on the H.V. side with the L.V. terminals short-circuited. Find the approximate current and the power factor of each
transformer when working in parallel with each other on the high and low voltage sides and taking a total load of 150 kW at a p.f. of
0.8 lagging from the high voltage bus bars.
Transcribed Image Text:Two 6600/250-V transformers have the following short-circuit characteristics: Applied voltage 200 V, current 30 A, power input 1,200 W for one of the transformers; the corresponding data for the other transformer being 120 V, 20 and 1,500 W. All value are measured on the H.V. side with the L.V. terminals short-circuited. Find the approximate current and the power factor of each transformer when working in parallel with each other on the high and low voltage sides and taking a total load of 150 kW at a p.f. of 0.8 lagging from the high voltage bus bars.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,