The three phase power and line-line ratings of the below electric power system is given below: T Vm M G: 50 MVA 11 KV - X= 4% T: 50 MVA 11/20 KV X= 4% M: 43.2 MVA 18 KV X= 4% By choosing 100 MVA and 11 KV on the generator side as base values, the new per unit impedance of the generator is and the new perunit impedance of the motor is

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
O e. None of these
Clear my choice
The three phase power and line-line ratings of the below electric power system is given below:
Vm
ut of
M
G: 50 MVA
11 KV
X= 4%
T: 50 MVA
11/20 KV
X= 4%
M: 43.2 MVA
18 KV
X= 4%
By choosing 100 MVA and 11 KV on the generator side as base values, the new per unit impedance of the generator is
and the new perunit impedance of the motor is
4
A three-phase, 60-Hz lossless transmission line is 350 Km long. The line has a phase constant B of 0.001266825 rad/Km and a su
impedance Z of 326.09 N. What is the total receiving end reactive power Qr when the sending end voltage is 230 KV and the re
voltage is 219 KV and the power angle & is 15 degrees?
out of
Transcribed Image Text:O e. None of these Clear my choice The three phase power and line-line ratings of the below electric power system is given below: Vm ut of M G: 50 MVA 11 KV X= 4% T: 50 MVA 11/20 KV X= 4% M: 43.2 MVA 18 KV X= 4% By choosing 100 MVA and 11 KV on the generator side as base values, the new per unit impedance of the generator is and the new perunit impedance of the motor is 4 A three-phase, 60-Hz lossless transmission line is 350 Km long. The line has a phase constant B of 0.001266825 rad/Km and a su impedance Z of 326.09 N. What is the total receiving end reactive power Qr when the sending end voltage is 230 KV and the re voltage is 219 KV and the power angle & is 15 degrees? out of
Expert Solution
steps

Step by step

Solved in 2 steps with 6 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,