The tension member shown in the figure below must resist a service dead load of 60 kips and a service live load of 45 kips. Does the member have enough strength? The steel is A588: Fy = 50 ksi, Fu = 70 ksi; and the bolts are 11/8 inches in diameter. Assume that Ae = An. О О PL 3/8 X 71/2 a. Use LRFD. Determine the design strength and the factored load. Make a conclusion about the member. (Express your answers to three significant figures.) Φι Ρη = kips kips Pu = -Select- b. Use ASD. Determine the allowable strength and required strength. Make a conclusion about the member. (Express your answers to three significant figures.) Ft Ae = Pa = -Select- kips kips
The tension member shown in the figure below must resist a service dead load of 60 kips and a service live load of 45 kips. Does the member have enough strength? The steel is A588: Fy = 50 ksi, Fu = 70 ksi; and the bolts are 11/8 inches in diameter. Assume that Ae = An. О О PL 3/8 X 71/2 a. Use LRFD. Determine the design strength and the factored load. Make a conclusion about the member. (Express your answers to three significant figures.) Φι Ρη = kips kips Pu = -Select- b. Use ASD. Determine the allowable strength and required strength. Make a conclusion about the member. (Express your answers to three significant figures.) Ft Ae = Pa = -Select- kips kips
Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter5: Beams
Section: Chapter Questions
Problem 5.12.2P
Related questions
Question
![The tension member shown in the figure below must resist a service dead load of
60 kips and a service live load of 45 kips. Does the member have enough
strength? The steel is A588: Fy = 50 ksi, Fu
=
70 ksi; and the bolts are 11/8
inches in diameter. Assume that Ae
=
An.
О
О
PL 3/8 X 71/2
a. Use LRFD.
Determine the design strength and the factored load. Make a conclusion about the
member.
(Express your answers to three significant figures.)
Φι Ρη
=
kips
kips
Pu
=
-Select-
b. Use ASD.
Determine the allowable strength and required strength. Make a conclusion about
the member.
(Express your answers to three significant figures.)
Ft Ae
=
Pa
=
-Select-
kips
kips](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F42a24f85-5b24-4859-8efe-76f4d02d81b5%2F5c9aa509-e925-4897-a486-077aa08fb94e%2Fnnozrjk_processed.png&w=3840&q=75)
Transcribed Image Text:The tension member shown in the figure below must resist a service dead load of
60 kips and a service live load of 45 kips. Does the member have enough
strength? The steel is A588: Fy = 50 ksi, Fu
=
70 ksi; and the bolts are 11/8
inches in diameter. Assume that Ae
=
An.
О
О
PL 3/8 X 71/2
a. Use LRFD.
Determine the design strength and the factored load. Make a conclusion about the
member.
(Express your answers to three significant figures.)
Φι Ρη
=
kips
kips
Pu
=
-Select-
b. Use ASD.
Determine the allowable strength and required strength. Make a conclusion about
the member.
(Express your answers to three significant figures.)
Ft Ae
=
Pa
=
-Select-
kips
kips
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 3 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Steel Design (Activate Learning with these NEW ti…](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning
![Steel Design (Activate Learning with these NEW ti…](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning