The single-line diagram of a three-phase power system is shown in below Figure. Equipment ratings are given as follows: Synchronous generators: GI 1000 MVA G2 1000 MVA G3 500 MVA 750 MVA G4 Transformers: TI T2 T3 T4 1000 MVA 1000 MVA 500 MVA 750 MVA Transmission lines: 500 kV 500 kV 500 kV 1-2 1-3 2-3 15 kV 15 kV 13.8 kV 13.8 kV b) XdX2= 0.18, Xo = 0.07 per unit Xd" = X2=0.20, Xo = 0.10 per unit Xd X2= 0.15, Xo = 0.05 per unit Xa=0.30, X₂=0.40, Xo = 0.10 per unit 15 kV A/500 kV Y 15 kV A/500 kV Y 15 kV Y/500 kV Y 15 kV Y/500 kV Y X = 0.10 per unit X= 0.10 per unit X = 0.12 per unit X=0.11 per unit Χι = 50 Ω, Χ = 150 Ω X₁40 S2, Xo= 100 2 Xy = 40 Ω, Χο = 100 Ω a) The inductor connected to Generator 3 neutral has a reactance of 0.05 per unit using generator 3 ratings as a base. Draw the zero-, positive-, and negative-sequence reactance diagrams using a 1000-MVA, 500-kV base in the zone of line 1-2. Neglect the A-Y transformer phase shifts. Faults at bus 1 are of interest. Determine the Thévenin equivalent of each sequence network as viewed from the fault bus 1. Prefault voltage is 1.0 per unit. Prefault load currents and A-Y transformer phase shifts are neglected. (Hint: Use the Y-A conversion.) Determine the subtransient fault current in per-unit and in kA during a bolted three-phase fault at the fault bus 1.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
The single-line diagram of a three-phase power system is shown in below Figure.
Equipment ratings are given as follows:
Synchronous generators:
GI
1000 MVA
G2
1000 MVA
G3 500 MVA
750 MVA
G4
Transformers:
TI
T2
T3
T4
1000 MVA
1000 MVA
500 MVA
750 MVA
Transmission lines:
500 kV
500 kV
500 kV
1-2
1-3
2-3
b)
15 kV
15 kV
13.8 kV
13.8 kV
d)
XdX2= 0.18, Xo = 0.07 per unit
Xd" = X2=0.20, Xo = 0.10 per unit
Xd X2= 0.15, Xo = 0.05 per unit
Xa=0.30, X₂=0.40, Xo = 0.10 per unit
15 kV A/500 kV Y
15 kV A/500 kV Y
15 kV Y/500 kV Y
15 kV Y/500 kV Y
X = 0.10 per unit
X= 0.10 per unit
X = 0.12 per unit
X=0.11 per unit
a)
The inductor connected to Generator 3 neutral has a reactance of 0.05 per unit
using generator 3 ratings as a base. Draw the zero-, positive-, and negative-sequence
reactance diagrams using a 1000-MVA, 500-kV base in the zone of line 1-2. Neglect
the A-Y transformer phase shifts.
Χι = 50 Ω, Χ = 150 Ω
X₁40 S2, Xo= 100 2
Xy = 40 Ω, Χο = 100 Ω
Faults at bus 1 are of interest. Determine the Thévenin equivalent of each
sequence network as viewed from the fault bus 1. Prefault voltage is 1.0 per unit.
Prefault load currents and A-Y transformer phase shifts are neglected. (Hint: Use the
Y-A conversion.)
Determine the subtransient fault current in per-unit and in kA during a bolted
three-phase fault at the fault bus 1.
Determine the subtransient fault current in per-unit and in kA, as well as the
per-unit line-to-ground voltages at the fault bus for a bolted single line-to-ground
fault at the faul Page 3 / 5
Q
+
Transcribed Image Text:The single-line diagram of a three-phase power system is shown in below Figure. Equipment ratings are given as follows: Synchronous generators: GI 1000 MVA G2 1000 MVA G3 500 MVA 750 MVA G4 Transformers: TI T2 T3 T4 1000 MVA 1000 MVA 500 MVA 750 MVA Transmission lines: 500 kV 500 kV 500 kV 1-2 1-3 2-3 b) 15 kV 15 kV 13.8 kV 13.8 kV d) XdX2= 0.18, Xo = 0.07 per unit Xd" = X2=0.20, Xo = 0.10 per unit Xd X2= 0.15, Xo = 0.05 per unit Xa=0.30, X₂=0.40, Xo = 0.10 per unit 15 kV A/500 kV Y 15 kV A/500 kV Y 15 kV Y/500 kV Y 15 kV Y/500 kV Y X = 0.10 per unit X= 0.10 per unit X = 0.12 per unit X=0.11 per unit a) The inductor connected to Generator 3 neutral has a reactance of 0.05 per unit using generator 3 ratings as a base. Draw the zero-, positive-, and negative-sequence reactance diagrams using a 1000-MVA, 500-kV base in the zone of line 1-2. Neglect the A-Y transformer phase shifts. Χι = 50 Ω, Χ = 150 Ω X₁40 S2, Xo= 100 2 Xy = 40 Ω, Χο = 100 Ω Faults at bus 1 are of interest. Determine the Thévenin equivalent of each sequence network as viewed from the fault bus 1. Prefault voltage is 1.0 per unit. Prefault load currents and A-Y transformer phase shifts are neglected. (Hint: Use the Y-A conversion.) Determine the subtransient fault current in per-unit and in kA during a bolted three-phase fault at the fault bus 1. Determine the subtransient fault current in per-unit and in kA, as well as the per-unit line-to-ground voltages at the fault bus for a bolted single line-to-ground fault at the faul Page 3 / 5 Q +
Line 1-2
Line 1-3
2
2
T₂
Line 2-3
3
T3
38
TA
38
21 Ý
3
4
youthiy
Transcribed Image Text:Line 1-2 Line 1-3 2 2 T₂ Line 2-3 3 T3 38 TA 38 21 Ý 3 4 youthiy
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 11 steps with 12 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,