The manufacturer of a product that is subjected to repetitive cycles has specified that the product should be removed from service when any crack reaches 15% of the critical crack length required to cause fracture. Consider a crack that is initially 0.02 mm long in a material with a fracture toughness of 55 MPaVm. The product is continuously cycled between compres- sive and tensile stresses of 300 MPa at a constant frequency. Assume external cracks for whichƒ= 1.12. The materials constants for these units are n- 3.4 and C- 2x 10-1. (a) What is the critical crack length required to cause fracture? (b) How many cycles will cause product failure? (c) If the product is removed from service as specified by the manufacturer, how much of the useful life of the product remains?

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
The manufacturer of a product that is
subjected to repetitive cycles has specified
that the product should be removed from
service when any crack reaches 15% of
the critical crack length required to cause
fracture.
Consider a crack that is initially
0.02 mm long in a material with a fracture
toughness of 55 MPaVm. The product
is continuously cycled between compres-
sive and tensile stresses of 300 MPa at
a constant frequency. Assume external
cracks for whichƒ= 1.12. The materials
constants for these units are n- 3.4 and
C- 2x 10-1.
(a) What is the critical crack length
required to cause fracture?
(b) How many cycles will cause product
failure?
(c) If the product is removed from service
as specified by the manufacturer, how
much of the useful life of the product
remains?
Transcribed Image Text:The manufacturer of a product that is subjected to repetitive cycles has specified that the product should be removed from service when any crack reaches 15% of the critical crack length required to cause fracture. Consider a crack that is initially 0.02 mm long in a material with a fracture toughness of 55 MPaVm. The product is continuously cycled between compres- sive and tensile stresses of 300 MPa at a constant frequency. Assume external cracks for whichƒ= 1.12. The materials constants for these units are n- 3.4 and C- 2x 10-1. (a) What is the critical crack length required to cause fracture? (b) How many cycles will cause product failure? (c) If the product is removed from service as specified by the manufacturer, how much of the useful life of the product remains?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 2 images

Blurred answer
Knowledge Booster
Crack detection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning