The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power supply: [10] Load 1: Heating load of P kW at unity P.F where is the last two digits (from right) of your registration number (i.e for the student that has a registration number 202112396, P = 96) Load 2: 240 kW induction motor at 0.60 lagging power factor. Find: 1- Total load in kVA and overall P.F of these two loads.. 2- Line current supplied by the source to feed these loads. 3- The leading power factor of the 200 kW synchronous motor that should be connected in parallel with these loads in order to to improve the power factor to be 0.95. 4- Line current supplied by the source to feed these loads after connecting the synchronous motor.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.21P: An industrial plant consisting primarily of induction motor loads absorbs 500 kW at 0.6 power factor...
icon
Related questions
Question

notice that P=38 For this question 

The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power
supply: [10]
Load 1: Heating load of P kW at unity P.F where is the last two digits
(from right) of
your registration number (i.e for the student that has a
registration number
202112396, P = 96)
Load 2: 240 kW induction motor at 0.60 lagging power factor.
Find:
1- Total load in kVA and overall P.F of these two loads..
2- Line current supplied by the source to feed these loads.
3- The leading power factor of the 200 kW synchronous motor that should
be connected in parallel with these loads in order to to improve the power factor
to be 0.95.
4- Line current supplied by the source to feed these loads after connecting
the synchronous motor.
Transcribed Image Text:The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power supply: [10] Load 1: Heating load of P kW at unity P.F where is the last two digits (from right) of your registration number (i.e for the student that has a registration number 202112396, P = 96) Load 2: 240 kW induction motor at 0.60 lagging power factor. Find: 1- Total load in kVA and overall P.F of these two loads.. 2- Line current supplied by the source to feed these loads. 3- The leading power factor of the 200 kW synchronous motor that should be connected in parallel with these loads in order to to improve the power factor to be 0.95. 4- Line current supplied by the source to feed these loads after connecting the synchronous motor.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Winding and Construction of the Rotor and Stator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning