synchronous generator of 100 MVA, 14.4kv, power factor 0.8 lagging, connected in Y, has a resistor in the armature negligible, a synchronous reactance of 1.0 per unit and a speed drop of 3%. The generator is connected in parallel with an infinite bus of 60hz and 14.4kv. a) What is the synchronous reactance of the generator in ohms? b) what is the internal voltage generated in nominal conditions? c) what is the frequency without load of the generator so that it delivers the nominal power of the system?
Load flow analysis
Load flow analysis is a study or numerical calculation of the power flow of power in steady-state conditions in any electrical system. It is used to determine the flow of power (real and reactive), voltage, or current in a system under any load conditions.
Nodal Matrix
The nodal matrix or simply known as admittance matrix, generally in engineering term it is called Y Matrix or Y bus, since it involve matrices so it is also referred as a n into n order matrix that represents a power system with n number of buses. It shows the buses' nodal admittance in a power system. The Y matrix is rather sparse in actual systems with thousands of buses. In the power system the transmission cables connect each bus to only a few other buses. Also the important data that one needs for have a power flow study is the Y Matrix.
Types of Buses
A bus is a type of system of communication that transfers data between the components inside a computer or between two or more computers. With multiple hardware connections, the earlier buses were parallel electrical wires but the term "bus" is now used for any type of physical arrangement which provides the same type of logical functions similar to the parallel electrical bus. Both parallel and bit connections are used by modern buses. They can be wired either electrical parallel or daisy chain topology or are connected by hubs which are switched same as in the case of Universal Serial Bus or USB.
A synchronous generator of 100 MVA, 14.4kv, power factor 0.8
lagging, connected in Y, has a resistor in the
armature negligible, a synchronous reactance of 1.0 per unit
and a speed drop of 3%. The generator is connected in parallel
with an infinite bus of 60hz and 14.4kv.
a) What is the synchronous reactance of the generator in ohms?
b) what is the internal voltage generated in nominal conditions?
c) what is the frequency without load of the generator so that it delivers the nominal power of the system?
d) Assume that the generator initially operates at nominal conditions. if it decreases 5%
generated internal voltage Ea, what will be the new armature current Ia?