Source: Ean = 12020° v; Eon = 1202 – 120° v; Een = 1204120° v (grounded neutral) Zan = Zpn = Zen = 0.1 + j1.5 N Line Impedance: Zline a = Zline b = Ztine c = 1 +j2 N; Load Impedance: Load 2b: Zan = 12 + j9 N; Zpn = 12 – j9 N; Zen = 15 + j0 N (ungrounded neutral) Find: Under Unbalanced Condition With Faults: a. Load Line Currents (Ia, Ib,Ic); b. Load Line Voltages (Vab, Vpe, Vca); c. Load Power Profile (Pr, Qr,St,pfr); d. The Fault Current (If) Types of Faults to be Considered, assuming worst case scenario (Z, = 0): SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open)

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Fault Location 2: Load Side
30 Source
ZLine
30 Load
Source:
Ean = 12020° v; Epn = 1204 – 120° v; Een = 1204120° v (grounded neutral)
Zan = Zbn = Zen = 0.1 + j1.5 N
Line Impedance:
Zine a = Ztine b = Zline c = 1 + j2 N;
Load Impedance:
Load 2b: Zan = 12 + j9 N; Zpm = 12 – j9 N; Zen = 15 + j0 2 (ungrounded neutral)
Find:
Under Unbalanced Condition With Faults:
a. Load Line Currents (Ia, Ib, Ie);
b. Load Line Voltages (Vab, Vpc, Vca);
c. Load Power Profile (Pr, QT, ST,pfr);
d. The Fault Current (If)
Types of Faults to be Considered, assuming worst case scenario (Z, = 0):
SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open)
Transcribed Image Text:Fault Location 2: Load Side 30 Source ZLine 30 Load Source: Ean = 12020° v; Epn = 1204 – 120° v; Een = 1204120° v (grounded neutral) Zan = Zbn = Zen = 0.1 + j1.5 N Line Impedance: Zine a = Ztine b = Zline c = 1 + j2 N; Load Impedance: Load 2b: Zan = 12 + j9 N; Zpm = 12 – j9 N; Zen = 15 + j0 2 (ungrounded neutral) Find: Under Unbalanced Condition With Faults: a. Load Line Currents (Ia, Ib, Ie); b. Load Line Voltages (Vab, Vpc, Vca); c. Load Power Profile (Pr, QT, ST,pfr); d. The Fault Current (If) Types of Faults to be Considered, assuming worst case scenario (Z, = 0): SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open)
Expert Solution
steps

Step by step

Solved in 7 steps with 7 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,