Solve the given problems below.. Use load combination of 1.2DL + 1.6LL 1. A column 450mm square with fc' = 27.65 MPa reinforced with 8-25mmø or Fy= 348 Mpa supports a dead load of 1000 kN and a live load of 780 kN. The allowable bearing pressure is 240 KPa. The base of footing is 1.5m below the grade. Assume the weight of soil and concrete to have an average unit weight of 19.7kn/m3. The total depth of footing is 550mm with an effective depth of 475mm. Determine the following: 1) dimension of footing. 2) Value of two-way or punching shear force (Vu) 3) Value of one-way beam factored shear force (Vu) 4) Required moment for strength design (Mu) 5) No. of 25mmø bars in each direction.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

FOUNDATION AND RETAINING WALL 1

Solve the given problems below. Use load combination of 1.2DL + 1.6LL
1. A column 450mm square with fc' = 27.65 MPa reinforced with 8-25mmø or Fy= 348 Mpa
supports a dead load of 1000 kN and a live load of 780 kN. The allowable bearing pressure is
240 KPa. The base of footing is 1.5m below the grade. Assume the weight of soil and concrete
to have an average unit weight of 19.7kn/m3. The total depth of footing is 550mm with an
effective depth of 475mm. Determine the following:
1) dimension of footing.
2) Value of two-way or punching shear force (Vu)
3) Value of one-way beam factored shear force (Vu)
4) Required moment for strength design (Mu)
5) No. of 25mmø bars in each direction.
Transcribed Image Text:Solve the given problems below. Use load combination of 1.2DL + 1.6LL 1. A column 450mm square with fc' = 27.65 MPa reinforced with 8-25mmø or Fy= 348 Mpa supports a dead load of 1000 kN and a live load of 780 kN. The allowable bearing pressure is 240 KPa. The base of footing is 1.5m below the grade. Assume the weight of soil and concrete to have an average unit weight of 19.7kn/m3. The total depth of footing is 550mm with an effective depth of 475mm. Determine the following: 1) dimension of footing. 2) Value of two-way or punching shear force (Vu) 3) Value of one-way beam factored shear force (Vu) 4) Required moment for strength design (Mu) 5) No. of 25mmø bars in each direction.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Sizing joists and rafters
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning