respectively. The 80% return air is mixed with 20% fresh air and then passed The room design conditions are 25 °C DBT and 50% RH, when outside design condition 5- Refrigeration load of the air conditioning plant in Ton. 5 kW through a cooling coil of 0.15 bypass factor. Determine 1- Apparatus dew point temperature. 2- Conditions of air leaving cooling coil. 3- Air flow rate into the room in m'/s. 4- Flow rate of fresh air and recirculated air in m'/min. 5- Refrigeration load of the air conditioning plant in Ton.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
are 43 °C DBT and 27.5°C WBT. The room sensible and latent heat loads are 20 kW an-
The room design conditions are 25 °C DBT and 50 % RH, when outside design conditio
5 kW respectively. The 80% return air is mixed with 20% fresh air and then passed
5- Refrigeration load of the air conditioning plant in Ton.
through a cooling coil of 0.15 bypass factor. Determine
1- Apparatus dew point temperature.
2- Conditions of air leaving cooling coil.
3- Air flow rate into the room in m'/s.
4- Flow rate of fresh air and recirculated air in m'/min.
5- Refrigeration load of the air conditioning plant in Ton.
Transcribed Image Text:are 43 °C DBT and 27.5°C WBT. The room sensible and latent heat loads are 20 kW an- The room design conditions are 25 °C DBT and 50 % RH, when outside design conditio 5 kW respectively. The 80% return air is mixed with 20% fresh air and then passed 5- Refrigeration load of the air conditioning plant in Ton. through a cooling coil of 0.15 bypass factor. Determine 1- Apparatus dew point temperature. 2- Conditions of air leaving cooling coil. 3- Air flow rate into the room in m'/s. 4- Flow rate of fresh air and recirculated air in m'/min. 5- Refrigeration load of the air conditioning plant in Ton.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The