R134a refrigeration system operates in an ideal vapor-compression refrigeration cycle. The temperature of the condenser and evaporator are 46 C and -2 C respectively. The cooling effect of the refrigerator is 15 kW. Calculate a) mass flow rate of the refrigerant b) work input to the compressor c) heat rejection in the condenser d) what is the maximum COP if this refrigerator operates in Carnot refrigeration cycle? *

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
R134a refrigeration system operates in an ideal vapor-compression refrigeration cycle. The temperature of the condenser and evaporator are 46 C and -2 C respectively. The cooling effect of the refrigerator is 15 kW. Calculate a) mass flow rate of the refrigerant b) work input to the compressor c) heat rejection in the condenser d) what is the maximum COP if this refrigerator operates in Carnot refrigeration cycle? * [ a)04s7kgrs 01136 ky/s )0739kg/s O a)0327kars b) 2.45kW O vasrkw b)134ky/s b)3.306 kw O o2342kw ) 18.294 kW 1161 kW O g97kw d)556 O d400 43712 d4)6.872
R134a refrigeration system operates in an ideal vapor-compression
refrigeration cycle. The temperature of the condenser and evaporator are
46 C and -2 C respectively. The cooling effect of the refrigerator is 15 kW.
Calculate a) mass flow rate of the refrigerant b) work input to the
compressor c) heat rejection in the condenser d) what is the maximum
COP if this refrigerator operates in Carnot refrigeration cycle? *
a) 0.457 kg/s
a) 0.1136 kg/s
a) 0.739 kg/s
a) 0.327 kg/s
b) 2.45 kw
b) 4.67 kw
b) 1.34 kg/s
b) 3.306 kW
c) 23.42 kW
c) 18.294 kW
c) 11.61 kw
c) 9.79 kw
d) 5.646
d) 4.09
d) 3.712
d) 6.872
Transcribed Image Text:R134a refrigeration system operates in an ideal vapor-compression refrigeration cycle. The temperature of the condenser and evaporator are 46 C and -2 C respectively. The cooling effect of the refrigerator is 15 kW. Calculate a) mass flow rate of the refrigerant b) work input to the compressor c) heat rejection in the condenser d) what is the maximum COP if this refrigerator operates in Carnot refrigeration cycle? * a) 0.457 kg/s a) 0.1136 kg/s a) 0.739 kg/s a) 0.327 kg/s b) 2.45 kw b) 4.67 kw b) 1.34 kg/s b) 3.306 kW c) 23.42 kW c) 18.294 kW c) 11.61 kw c) 9.79 kw d) 5.646 d) 4.09 d) 3.712 d) 6.872
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Power Plant Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY