Question 53 A 250 ft long span separates a dc power supply from a lamp which draws 25 A of current. If 14 AWG wire is used (note that two wires are needed for a total of 500 ft), calculate the amount of power wasted in the wire. TABLE 2.4 Some Common Wire Gauges and the Resistance of (Soft) Solid Copper Wire* Conductor Size (AWG) 28 24 22 18 14 12 6 4 2 Cross-Sectional Area (mm²) 0.0804 0.205 0.324 0.823 2.08 3.31 13.3 21.1 33.6 Ohms per 1000 ft at 20°C 65.3 25.7 16.2 6.39 2.52 1.59 0.3952 0.2485 0.1563 * C. B. Rawlins et al., Standard Handbook for Electrical Engineering, 13th ed., D. G. Fink and H. W. Beaty, eds. New York: McGraw-Hill, 1993, p. 4-47.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Question 53
A 250 ft long span separates a dc power supply from a lamp which draws 25 A of current. If 14 AWG
wire is used (note that two wires are needed for a total of 500 ft), calculate the amount of power wasted in
the wire.
TABLE 2.4 Some Common Wire Gauges and the Resistance of (Soft)
Solid Copper Wire*
Conductor Size (AWG)
28
24
22
18
14
12
6
4
2
Cross-Sectional Area (mm²)
0.0804
0.205
0.324
0.823
2.08
3.31
13.3
21.1
33.6
Ohms per 1000 ft at 20°C
65.3
25.7
16.2
6.39
2.52
1.59
0.3952
0.2485
0.1563
* C. B. Rawlins et al., Standard Handbook for Electrical Engineering, 13th ed., D. G. Fink and H. W. Beaty, eds. New York:
McGraw-Hill, 1993, p. 4-47.
Transcribed Image Text:Question 53 A 250 ft long span separates a dc power supply from a lamp which draws 25 A of current. If 14 AWG wire is used (note that two wires are needed for a total of 500 ft), calculate the amount of power wasted in the wire. TABLE 2.4 Some Common Wire Gauges and the Resistance of (Soft) Solid Copper Wire* Conductor Size (AWG) 28 24 22 18 14 12 6 4 2 Cross-Sectional Area (mm²) 0.0804 0.205 0.324 0.823 2.08 3.31 13.3 21.1 33.6 Ohms per 1000 ft at 20°C 65.3 25.7 16.2 6.39 2.52 1.59 0.3952 0.2485 0.1563 * C. B. Rawlins et al., Standard Handbook for Electrical Engineering, 13th ed., D. G. Fink and H. W. Beaty, eds. New York: McGraw-Hill, 1993, p. 4-47.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,